help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Published ahead of print on September 5, 2002, doi:10.1164/rccm.200209-999OC
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Online Data Supplement
Right arrow All Versions of this Article:
200209-999OCv1
166/11/1423    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Parthasarathy, S.
Right arrow Articles by Tobin, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parthasarathy, S.
Right arrow Articles by Tobin, M. J.
American Journal of Respiratory and Critical Care Medicine Vol 166. pp. 1423-1429, (2002)
© 2002 American Thoracic Society


Original Article

Effect of Ventilator Mode on Sleep Quality in Critically Ill Patients

Sairam Parthasarathy and Martin J. Tobin

Division of Pulmonary and Critical Care Medicine, Edward Hines, Jr. Veterans Administrative Hospital, Hines, Illinois; and Loyola University of Chicago Stritch School of Medicine, Maywood, Illinois

Correspondence and requests for reprints should be addressed to Martin J. Tobin, M.D., Division of Pulmonary and Critical Care Medicine, Edward Hines, Jr. Veterans Administrative Hospital, Route 111N, Hines, IL 60141. E-mail: mtobin2{at}lumc.edu

To determine whether sleep quality is influenced by the mode of mechanical ventilation, we performed polysomnography on 11 critically ill patients. Because pressure support predisposes to central apneas in healthy subjects, we examined whether the presence of a backup rate on assist-control ventilation would decrease apnea-related arousals and improve sleep quality. Sleep fragmentation, measured as the number of arousals and awakenings, was greater during pressure support than during assist-control ventilation: 79 ± 7 versus 54 ± 7 events per hour (p = 0.02). Central apneas occurred during pressure support in six patients; heart failure was more common in these six patients than in the five patients without apneas: 83 versus 20% (p = 0.04). Among patients with central apneas, adding dead space decreased sleep fragmentation: 44 ± 6 versus 83 ± 12 arousals and awakenings per hour (p = 0.02). Changes in sleep–wakefulness state caused greater changes in breath components and end-tidal CO2 during pressure support than during assist-control ventilation. In conclusion, inspiratory assistance from pressure support causes hypocapnia, which combined with the lack of a backup rate and wakefulness drive can lead to central apneas and sleep fragmentation, especially in patients with heart failure.

Key Words: arousal • artificial respiration • critical illness • mechanical ventilator • sleep




This article has been cited by other articles:


Home page
Eur Respir JHome page
J-M. Boles, J. Bion, A. Connors, M. Herridge, B. Marsh, C. Melot, R. Pearl, H. Silverman, M. Stanchina, A. Vieillard-Baron, et al.
Weaning from mechanical ventilation
Eur. Respir. J., May 1, 2007; 29(5): 1033 - 1056.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. A. Hardin, M. Seyal, T. Stewart, and H. W. Bonekat
Sleep in Critically Ill Chemically Paralyzed Patients Requiring Mechanical Ventilation
Chest, June 1, 2006; 129(6): 1468 - 1477.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
M. M. J. De Jong, S. M. Burns, M. L. Campbell, M. Chulay, M. J. Grap, L. N.B. Pierce, and T. Simpson
Development of the American Association of Critical-Care Nurses' Sedation Assessment Scale for Critically Ill Patients
Am. J. Crit. Care., November 1, 2005; 14(6): 531 - 544.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. G. Johnson and D. C. Johnson
Bilevel Positive Airway Pressure Worsens Central Apneas During Sleep
Chest, October 1, 2005; 128(4): 2141 - 2150.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
F. Fanfulla, M. Delmastro, A. Berardinelli, N. D. Lupo, and S. Nava
Effects of Different Ventilator Settings on Sleep and Inspiratory Effort in Patients with Neuromuscular Disease
Am. J. Respir. Crit. Care Med., September 1, 2005; 172(5): 619 - 624.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
V. F. Parreira, V. Jounieaux, D. O. Rodenstein, S. Parthasarathy, and M. J. Tobin
Disrupted Sleep during Mechanical Ventilation
Am. J. Respir. Crit. Care Med., November 15, 2003; 168(10): 1252 - 1253.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
E. Kondili, G. Prinianakis, and D. Georgopoulos
Patient-ventilator interaction
Br. J. Anaesth., July 1, 2003; 91(1): 106 - 119.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. Tobin
Critical Care Medicine in AJRCCM 2002
Am. J. Respir. Crit. Care Med., February 1, 2003; 167(3): 294 - 305.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. Tobin
Sleep-Disordered Breathing, Control of Breathing, Respiratory Muscles, and Pulmonary Function Testing in AJRCCM 2002
Am. J. Respir. Crit. Care Med., February 1, 2003; 167(3): 306 - 318.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 2002 American Thoracic Society