Comparison of an Interferon-
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ABSTRACT |
|---|
|
|
|---|
release assays are approved for the diagnosis of latent tuberculosis infection (LTBI), limited data exist regarding their performance in HIV infection.
Objectives: To compare tuberculin skin test (TST) results to the commercial IFN-
release assay QuantiFERON-TB Gold In-Tube (QFT) for the diagnosis of LTBI in HIV-infected adults.
Methods: A total of 294 HIV-infected subjects sampled from two San Francisco cohorts underwent TST, using 5 TU of purified protein derivative, and QFT, measuring IFN-
response to Mycobacterium tuberculosisspecific RD-1 antigens.
Main Results: Of 294 participants, 205 (70%) returned for an evaluable TST. Concordance between QFT and TST was 89.3% (kappa = 0.37, p = 0.007). However, in subjects with positive test results by either TST or QFT, only 28% (8/29) had positive test results by both modalities. TST-positive/QFT-negative discordant results were found in 5.1% of subjects and TST-negative/QFT-positive discordance in 5.6%. Indeterminate QFT results occurred in 5.1%, all due to a failure to respond to the phytohemagglutinin-positive control. Subjects with a CD4+ count of less than 100 cells/mm3 had a relative risk of an indeterminate result of 4.24 (95% confidence interval, 1.5511.61; p= 0.003) compared with those with a CD4+ count of 100 or more.
Conclusions: Overall concordance between QFT and TST in HIV infection was high, but agreement among subjects with positive tests by either modality was low.
Key Words: latent tuberculosis infection human immunodeficiency virus QuantiFERON interferon-
assay tuberculin skin test
Scientific Knowledge on the Subject Although interferon- assays are promising alternatives to the tuberculin skin test, there are limited data on the performance of these diagnostics in the HIV-infected population, in whom latent tuberculosis infection diagnosis and treatment is a priority.
What This Study Adds to the Field
|
However, LTBI diagnosis traditionally relies on the tuberculin skin test (TST), which is limited by the need for two visits, an often dismal return rate for evaluation (3, 4), the subjective nature of test placement and interpretation, and false-positive reactions from bacille Calmette-Guérin (BCG) vaccination and nontuberculous mycobacterium exposure. In addition, HIV-infected patients have a higher rate of anergy, particularly with advanced immunosuppression (5, 6).
Recently developed interferon (IFN)-
release assays (IGRAs) using the Mycobacterium tuberculosisspecific antigens early secreted antigenic target 6 (ESAT-6) and culture filtrate protein 10 (CFP-10) have shown promise as alternative diagnostic tools for LTBI. Tests using these TB-specific antigens have the advantage of decreased cross-reactivity in individuals exposed to BCG, Mycobacterium avium, and most nontuberculous mycobacteria (7). In the QuantiFERON-TB Gold assay (Cellestis, Carnegie, Australia), antigens are incubated with whole blood, after which lymphocyte release of IFN-
is quantified by ELISA. An alternative assay, the enzyme-linked immunospot (ELISPOT) T-SPOT.TB assay (Oxford Immunotec, Oxford, UK), uses purified lymphocytes incubated with TB antigens and measures the number of IFN-
releasing cells. Compared with TST, data on the current generation of IGRAs suggest higher specificity (8), fewer false-positive reactions due to BCG vaccination (9), and greater sensitivity given a known TB exposure in environments with low TB incidence (10).
However, there are limited data describing IGRA performance in HIV-infected individuals, whose immunologic impairment may affect the performance of these lymphocyte-based assays (11). To better understand IGRA use in HIV infection, we compared the performance of QuantiFERON-TB Gold In-Tube Test (QFT) with conventional TST for the diagnosis of LTBI in an urban HIV-infected population.
| METHODS |
|---|
|
|
|---|
25 cases/100,000), self-reported contact with an active TB case, and living, working, or volunteering in a homeless shelter, hospital, prison, drug rehabilitation unit, or nursing home.
IGRA
Blood was collected in three QFT evacuated tubes: one containing TB antigens (ESAT-6, CFP-10, and TB7.7), a positive control tube containing phytohemagglutinin, and a negative control tube. ELISA for IFN-
was performed according to the manufacturer's specifications. A positive result was defined as TB antigen minus negative control IFN-
of 0.35 IU/ml or more and 25% or more of negative control IFN-
value. Indeterminate results were defined as either (1) a negative control IFN-
level of more than 8.0 IU/ml or (2) a positive control IFN-
response of 0.5 IU/ml or less with a TB antigen minus a negative control IFN-
response of either less than 0.35 IU/ml or less than 25% of the negative control value (14). Because the IFN-
ELISA cannot accurately quantify values of more than 10 IU/ml, such values were treated as 10 IU/ml during analysis.
QFT packaging states that positive results can be confirmed when TB infection is not suspected by retesting the original samples in duplicate and considering an individual to have tested QFT positive if one or both of the replicate tests are positive (14). Samples initially classified as positive QFT results were retested in duplicate to evaluate how this recommendation would affect positive test results. These results are reported; however, QFT test results were classified on the basis of the initial QFT test only, as the population studied was at risk for TB infection.
TST
One-step tuberculin skin testing with 5 TU of tuberculin (Tubersol; Aventis Pasteur, Toronto, ON, Canada) was performed in accordance with American Thoracic Society guidelines (15). TST results were interpreted 48 to 72 hours after placement, and maximum transverse diameter of the induration was recorded using blinded calipers. Positive TST results were defined as an induration of 5 mm or larger (15).
All participants gave informed consent. Research was approved by the institutional review board.
Statistical Analyses
TST and QFT results were analyzed as continuous variables and as dichotomized binary values. A chi-square test was used to compare proportions, and median values were compared using the Mann-Whitney rank sum test. Trend analysis was performed using a nonparametric test for trend across ordered groups. Concordance between dichotomized TST and QFT results was evaluated using agreement and kappa statistics. Correlation calculations were performed using Spearman correlation.
| RESULTS |
|---|
|
|
|---|
|
|
|
IGRA
QFT testing yielded positive results in 8.5% (25/294) of subjects, negative results in 86.4% (254/294) of subjects, and indeterminate results in 5.1% (15/294) of subjects (Table 2). Duplicate testing of positive QFT samples resulted in 20% (5/25) of samples with two negative tests, 12% (3/25) with one positive/one negative test, and 68% (17/25) with two positive tests. All indeterminate results were due to a failure to respond adequately to the positive control. Of those with a CD4+ cell count of less than 100 cells/mm3, 16.1% (5/31) had indeterminate QFT results, compared with 3.6% (4/111) and 3.9% (6/152) in the CD4+ strata of 100 to 350 or more than 350 cells/mm3, respectively (p = 0.007). Subjects with a CD4+ count of less than 100 cells/mm3 had a relative risk of an indeterminate result of 4.24 (95% CI, 1.5511.61; p = 0.003) compared with those with a CD4+ count of 100 cells/mm3 or more.
Excluding indeterminate QFT results, unadjusted analysis revealed the following predictors of QFT positivity: CD4+ count of more than 350 cells/mm3 (OR, 3.17; 95% CI, 1.228.19; p = 0.02), prior positive TST (OR, 5.91; 95% CI, 2.4014.57; p < 0.001), birth in a country with a high TB incidence rate (OR, 3.17; 95% CI, 1.158.73; p = 0.03), and Latino ethnicity (OR, 5.85; 95% CI, 1.5122.73; p = 0.011). Controlling for current CD4+ count and ethnicity, prior positive TST and birth in a country with high TB incidence remained predictive of QFT positivity (Table 3).
|
release in response to TB antigens (rho = 0.12, p = 0.046) and with higher IFN-
response to positive control (rho = 0.31, p
0.001). Median IFN-
response to TB antigens was 0.12 IU/ml, 0.14 IU/ml, and 0.16 IU/ml at CD4+ cell counts of less than 100, 100 to 350, and more than 350 cells/mm3, respectively (p = 0.008, test for trend). TB antigeninduced IFN-
release was correlated with TST induration (rho = 0.2, p = 0.004).
Concordance between TST and IGRA
Excluding those with indeterminate QFTs and/or TSTs read outside 48 to 72 hours, 196 subjects had valid TST and QFT results. Of these, 167 (85.2%) were concordant in their negative results and 8 (4.1%) were concordant in their positive results, for an overall concordance of 89.3% (kappa = 0.37, p
0.001). Of subjects without valid TST results, 6.7% (6/89) had positive QFT results, and 6.7% (6/89) had indeterminate QFT results.
TST+/QFT discordant results were found in 5.1% (10/196) of subjects and TST/QFT+ results in 5.6% (11/196) of subjects. Of TST/QFT+ subjects, 45% (5/11) reported prior reactive TSTs, including 3 of 11 with previous isoniazid (INH) treatment. Sixty percent (6/10) of the TST+/QFT subjects reported prior reactive TSTs, all with subsequent INH therapy. Given that individuals with reactive TST results are generally not serially skin tested, this discordance would decrease to 2.4% (4/165) for TST+/QFT and 3.6% (6/165) for TST/QFT+, if all subjects reporting prior positive TSTs were excluded.
In unadjusted analysis, TST+/QFT discordance was predicted by prior positive TST (OR, 13.4; 95% CI, 3.3952.90; p < 0.001), higher CD4+ nadir (per 100 cells/mm3; OR, 1.33; 95% CI, 1.061.68; p = 0.013), lower HIV RNA log10 copies (OR, 0.40; 95% CI, 0.180.90; p = 0.027), Asian/Pacific Islander ethnicity (OR, 13; 95% CI, 1.42118.29; p = 0.023), and exposure to a shelter, prison, or drug rehabilitation unit (OR, 4.91; 95% CI, 1.0123.81; p = 0.048). TST/QFT+ discordance was predicted by prior positive TST (OR, 7.44; 95% CI, 2.0327.35; p = 0.002), CD4+ count of more than 350 cells/mm3 (OR, 11.67; 95% CI, 1.4693.37; p = 0.02), and birthplace in a county with high TB incidence rate (OR, 5.32; 95% CI, 1.2322.92; p = 0.025).
| DISCUSSION |
|---|
|
|
|---|
However, the discordance among subjects with a positive test using either modality raises concerns about the use of QFT in the HIV-infected population. Only 8 of 29 (28%) patients with a positive result on either QFT or TST had a positive result on both tests. Of the TST-positive results, 10 of 18 (56%) occurred in QFT-negative subjects; these positive TST results would have been missed if QFT were used alone.
TST/QFT+ results were found in 5.6% of subjects, which may be attributable to either false-positive QFT results or to improved sensitivity of QFT over TST. Given the absence of a diagnostic gold standard, it must be noted that the terms specificity and sensitivity in reference to LTBI are only estimations. In populations with low TB risk, estimated specificity of QFT for LTBI detection has been high, ranging from 96 to 99.8% (9, 10, 14, 23, 24). In the current study, subjects with TST/QFT+ results were more likely to have been born in countries with high TB incidence rates (OR, 5.1; 95% CI, 1.221.7; p = 0.03) than those with both negative QFT and TST results, which suggests increased sensitivity of QFT testing over TST, but which would require confirmation in a larger study.
The 5.1% of subjects with TST+/QFT discordant results raises concern about the recent Centers for Disease Control and Prevention guidelines recommending use of QFT testing "in all circumstances in which the TST is currently used"(25). If QFT were used as the sole diagnostic assay, these TST-positive results would no longer be captured, leaving the essential question, Do these individuals have true TB infection or false-positive TST results? False-positive TSTs occur with exposure to atypical mycobacteria, which cannot be excluded, and with previous BCG vaccination, which were reported by only 1 of 10 of these discordant subjects. Alternatively, these discordant results may indicate a diminished sensitivity of QFT compared with TST for LTBI diagnosis. However, two contact investigations using QFT found a strong relationship between QFT positivity and level of exposure, suggesting sensitivity equivalent to TST (16) or superior to TST (22). Alternatively, these TST+/QFT results may be explained by QFT reverting from positive to negative after LTBI therapy. Sixty percent of the TST+/QFT subjects reported prior reactive TSTs, all with subsequent INH therapy. IGRA response to therapy remains an area of controversy, because some studies have demonstrated declining IFN-
responses after LTBI or active TB treatment (2628), whereas others have shown unchanged or increasing IFN-
responses (24, 29, 30).
The intraassay variability encountered with repeat testing of the positive QFT samples raises concerns about QFT reproducibility in general. Twenty percent of the current study's positive QFT results could have been reclassified as negative with repeated testing of the initial specimen, and 32% (8/25) of subjects had at least one negative test result with duplicate testing. All result changes were due to small variations in the IFN-
response. This may reflect the imposition of a binary cutoff on a continuous laboratory measurement with some inherent measurement variability. However, further investigation of QFT intraassay variability, including variability in indeterminate and negative results as well, is merited. A South African study has also raised this issue of assay variability, finding a surprisingly low 75% concordance between QuantiFERON-TB Gold and the QuantiFERON-TB Gold In-Tube results, which have different methods of collection but use the same TB antigens and thus would be expected to yield very similar test results (21).
Similar to TST (5, 31, 32), QFT may be less sensitive in advanced HIV disease. Lower CD4+ cell count was associated with weaker IFN-
response to both TB antigens and to the positive control. Indeterminate results were more frequent in subjects with CD4+ counts of less than 100 cells/mm3 (16.1%) but did not differ in those with CD4+ counts of 100 to 350 versus counts of more than 350 cells/mm3 (3.6 vs. 3.9%, respectively). Danish HIV-infected subjects similarly demonstrated an elevated QFT indeterminate rate of 24% in those with CD4+ cell counts of less than 100 cells/mm3, compared with 2.8% in those with CD4+ counts of more than 100 cells/mm3 (11).
This study does not resolve the question of whether QFT testing should be done simultaneously with or in place of TST testing in HIV-infected patients. On the one hand, the significant risk of reactivation LTBI in HIV-infected subjects argues for simultaneous screening with both TST and QFT to minimize false-negative tests and missed opportunities for LTBI therapy. More than half of the TST-positive results occurred in QFT-negative subjects (10/18), and 40% (4/10) of TST+/QFT subjects had new TST-positive results that would otherwise have been missed with QFT testing alone. Using the ELISpot IGRA, a Gambian study of child contacts to active TB cases found discordance at both ends of the exposure spectrum: increased TST+/ IGRA at high-level exposure and increased TST/IGRA+ at low-level exposure (33). These results also suggest that, for maximal LTBI diagnosis, both IGRA and TST would have to be used simultaneously.
On the other hand, simultaneous QFT and TST may be unrealistic in many settings. In the United States, TST limitations, which include poor performance in HIV-infected populations (5, 6) and the personnel requirements for appropriate placement and interpretation, make a one-visit blood test attractive for LTBI diagnosis. In addition, the current study's high 70% return rate for TST interpretation is atypical; return rates are often in the range of 30% (3, 4), which further reduce TST sensitivity and can increase the cost of LTBI screening. Although TST might capture potential LTBI cases that QFT testing misses, the inconvenience and low completion rate that historically accompany TSTs may limit the practical application of simultaneous TST and QFT testing.
This study is limited by its cross-sectional design, which precludes prospective evaluation of TB incidence. In addition, the small number of subjects with CD4+ counts of less than 100 cells/mm3 hinders examination of QFT in advanced HIV. The low rate of positive TST and QFT tests limits evaluation of risk factors associated with test positivity and with discordance between the tests. However, the 8 to 9% rate of LTBI suggested by TST and QFT testing in this study is consistent with that seen in other industrialized populations with low TB prevalence (3436), where LTBI treatment is a clinical priority and where QFT testing will be feasible.
In conclusion, for diagnosis of LTBI in HIV-infected subjects, overall concordance between QFT and TST was high and similar to that seen in an immunocompetent population. However, among subjects with positive test results on either assay, the concordance was low (28%), which raises concern over implementation of QFT as a sole diagnostic for LTBI in this population. Until further data are available on the implication of discordant TST and QFT results, a strategy of simultaneous TST and QFT testing, where feasible, would maximize potential LTBI diagnoses in HIV-infected subjects. Duplicate testing of QFT-positive results as suggested by the manufacturer could have changed QFT results in 20% of subjects, which merits further evaluation of intraassay variability for all QFT results. Finally, QFT testing may be limited by an elevated rate of indeterminate results in subjects with CD4+ cell counts of less than 100 cells/mm3.
| Acknowledgments |
|---|
| FOOTNOTES |
|---|
This article has an online supplement, which is accessible from this issue's table of contents at www.atsjournals.org
Originally Published in Press as DOI: 10.1164/rccm.200608-1088OC on January 11, 2007
Conflict of Interest Statement: None of the authors has a financial relationship with a commercial entity that has an interest in the subject of this manuscript.
Received in original form August 3, 2006; accepted in final form January 11, 2007
| REFERENCES |
|---|
|
|
|---|
assay with tuberculin skin testing for the detection of tuberculosis infection in hospitalized children in rural India. J Infect 2007;54:267276.[CrossRef][Medline]
assays and tuberculin skin test for tracing tuberculosis contacts. Am J Respir Crit Care Med 2007;175:618627.
-based assay using new antigens. Am J Respir Crit Care Med 2004;170:5964.This article has been cited by other articles:
![]() |
X. Zhao, D. Mazlagic, E. A. Flynn, H. Hernandez, and C. L. Abbott Is the QuantiFERON-TB Blood Assay a Good Replacement for the Tuberculin Skin Test in Tuberculosis Screening?: A Pilot Study at Berkshire Medical Center Am J Clin Pathol, November 1, 2009; 132(5): 678 - 686. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Inoue, T. Nakamura, A. Katsuma, S. Masumoto, E. Minami, D. Katagiri, T. Hoshino, M. Shibata, M. Tada, and F. Hinoshita The value of QuantiFERON(R)TB-Gold in the diagnosis of tuberculosis among dialysis patients Nephrol. Dial. Transplant., July 1, 2009; 24(7): 2252 - 2257. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Richeldi, M. Losi, R. D'Amico, M. Luppi, A. Ferrari, C. Mussini, M. Codeluppi, S. Cocchi, F. Prati, V. Paci, et al. Performance of Tests for Latent Tuberculosis in Different Groups of Immunocompromised Patients Chest, July 1, 2009; 136(1): 198 - 204. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Mack, G. B. Migliori, M. Sester, H. L. Rieder, S. Ehlers, D. Goletti, A. Bossink, K. Magdorf, C. Holscher, B. Kampmann, et al. LTBI: latent tuberculosis infection or lasting immune responses to M. tuberculosis? A TBNET consensus statement Eur. Respir. J., May 1, 2009; 33(5): 956 - 973. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ruhwald, T. Bodmer, C. Maier, M. Jepsen, M. B. Haaland, J. Eugen-Olsen, P. Ravn, and on behalf of TBNET Evaluating the potential of IP-10 and MCP-2 as biomarkers for the diagnosis of tuberculosis Eur. Respir. J., December 1, 2008; 32(6): 1607 - 1615. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. H. Bothamley, L. Ditiu, G. B. Migliori, C. Lange, and TBNET contributors Active case finding of tuberculosis in Europe: a Tuberculosis Network European Trials Group (TBNET) survey Eur. Respir. J., October 1, 2008; 32(4): 1023 - 1030. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Choi, J. W. Shin, J. Y. Kim, I. W. Park, B. W. Choi, and M.-K. Lee The Effect of Previous Tuberculin Skin Test on the Follow-up Examination of Whole-Blood Interferon-{gamma} Assay in the Screening for Latent Tuberculosis Infection Chest, June 1, 2008; 133(6): 1415 - 1420. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Kobashi, K. Mouri, S. Yagi, Y. Obase, N. Miyashita, N. Okimoto, T. Matsushima, T. Kageoka, and M. Oka Clinical Utility of the QuantiFERON TB-2G Test for Elderly Patients With Active Tuberculosis Chest, May 1, 2008; 133(5): 1196 - 1202. [Abstract] [Full Text] [PDF] |
||||
![]() |
N Viget, G Vernier-Massouille, D Salmon-Ceron, Y Yazdanpanah, and J-F Colombel Opportunistic infections in patients with inflammatory bowel disease: prevention and diagnosis Gut, April 1, 2008; 57(4): 549 - 558. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. W. Yew and C. C. Leung Update in Tuberculosis 2007 Am. J. Respir. Crit. Care Med., March 1, 2008; 177(5): 479 - 485. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Proc. Am. Thorac. Soc. | Am. J. Respir. Cell Mol. Biol. |