Published ahead of print on March 24, 2005, doi:10.1164/rccm.200411-1479OC
© 2005 American Thoracic Society doi: 10.1164/rccm.200411-1479OC
Early Lung Cancer Detection Using Spiral Computed Tomography and Positron Emission TomographyDepartments of Radiology, Nuclear Medicine, Pathology, Pulmonary Medicine, and Thoracic Surgery, Clínica Universitaria; Department of Histology and Pathology, School of Medicine; and Division of Oncology, Center for Applied Medical Research (CIMA), Universidad de Navarra, Pamplona, Spain Correspondence and requests for reprints should be addressed to Javier J. Zulueta, M.D., Pulmonary Medicine, Clínica Universitaria, Avda. Pio XII, 36, 31008 Pamplona, Spain. E-mail: jzulueta{at}unav.es
Rationale: Lung cancer screening using computed tomography (CT) is effective in detecting lung cancer in early stages. Concerns regarding false-positive rates and unnecessary invasive procedures have been raised. Objective: To study the efficiency of a lung cancer protocol using spiral CT and F-18-fluorodeoxyglucose positron emission tomography (FDG-PET). Methods: High-risk individuals underwent screening with annual spiral CTs. Follow-up CTs were done for noncalcified nodules of 5 mm or greater, and FDG-PET was done for nodules 10 mm or larger or smaller (> 7 mm), growing nodules. Results: A total of 911 individuals completed a baseline CT study and 424 had at least one annual follow-up study. Of the former, 14% had noncalcified nodules of 5 mm or larger, and 3.6% had nodules of 10 mm or larger. Eleven nonsmall cell lung cancers (NSCLC) and one small cell lung cancer (SCLC) were diagnosed in the baseline study (prevalence rate, 1.32%), and two NSCLCs in the annual study (incidence rate, 0.47%). All NSCLCs (92% of prevalence cancers) were diagnosed in stage I (12 stage IA, 1 stage IB). FDG-PET was helpful for the correct diagnosis in 19 of 25 indeterminate nodules. The sensitivity, specificity, positive predictive value, and negative predictive value of FDG-PET for the diagnosis of malignancy were 69, 91, 90, and 71%, respectively. However, the sensitivity and negative predictive value of the screening algorithm, which included a 3-month follow-up CT for nodules with a negative FDG-PET, was 100%. Conclusion: A protocol for early lung cancer detection using spiral CT and FDG-PET is useful and may minimize unnecessary invasive procedures for benign lesions.
Key Words: chronic obstructive pulmonary disease lung neoplasm pulmonary nodule smoking Lung cancer is the most frequent and lethal malignancy in the world (13). Advances in the treatment of locally advanced lung cancer have had no impact on overall 5-year survival rates from this disease (1, 2). In countries where gains against tobacco smoking have been made, mortality rates from lung cancer have started to decrease, but future projections are not optimistic because of the recent surge in tobacco consumption among young people (4). And even if smoking could be reduced significantly, the long lag time between peak tobacco consumption and the development of clinical lung cancer will assure a long life for this epidemic. The main reason why more than 80% of patients with lung cancer die soon after diagnosis is that most patients are diagnosed in late nonsurgical stages (4). Large screening trials have investigated the use of conventional radiology and sputum cytology for early detection of lung cancer but failed to show a reduction in disease-specific mortality, resulting in public policies against screening for this disease (58). However, recently, very promising reports using spiral computed tomography (CT) have brought lung cancer screening back to the forefront. The Early Lung Cancer Action Project (ELCAP) demonstrated that low-dose spiral CT detects lung cancer in early stages much more effectively than conventional chest radiograph (9). Following a carefully designed protocol based on follow-up CTs to detect growth of small nodules, 86% of lung cancers diagnosed in asymptomatic individuals were in stage I (9). Other studies using spiral CT have found similar results, although with variations in the percentage of individuals with positive CTs (i.e., with noncalcified nodules that need further workup) (1014). Swensen and colleagues (10) reported noncalcified nodules in close to 70% of the individuals participating in a lung cancer screening trial with spiral CT. Diederich and coworkers (11) found noncalcified nodules in 43% of their population. Although the ELCAP investigators only performed one invasive procedure on one benign lesion (9), the high prevalence of noncalcified nodules may result in unnecessary invasive procedures for benign diseases. This will be of particular concern when these protocols become widely used in the community with less rigorous standards. Positron emission tomography with the glucose analog F-18-fluorodeoxyglucose (FDG-PET) is an accurate noninvasive imaging test for diagnosis of pulmonary nodules, although few data exist for nodules smaller than 1 cm in diameter (15). Pastorino and colleagues (12) showed that selective use of FDG-PET in a spiral CT-based lung cancer screening trial may be useful in avoiding biopsies for benign lesions. The hypothesis formulated in the study presented herein is that adding FDG-PET to a spiral CTbased early lung cancer detection protocol will avoid unnecessary procedures for benign lesions. Furthermore, false-negative lesions (i.e., cancers with no pathologic uptake on the FDG-PET) will be diagnosed with follow-up CTs to detect growth, and therefore such a protocol will not result in missed cancers because of negative PET scans. After publication of their original results, the ELCAP group led two important initiatives: the NY-ELCAP screening trial, a New Yorkarea multicenter trial projecting to screen 10,000 high-risk individuals with spiral CT, and the I-ELCAP, an international consortium that brings together investigators from over 30 centers from around the world (16). One of the main objectives of I-ELCAP is to pool data from screening trials underway in these centers. The current article presents results from an ongoing trial of lung cancer screening using spiral CT and FDG-PET conducted at our institution as a member of I-ELCAP since 2000. Some of the results of these studies have been previously reported in the form of an abstract (17).
Population Current and former smokers of at least 40 years of age, with a minimum 10 pack-year smoking history, and with no symptoms of lung cancer were invited to participate. A background questionnaire and written, informed consent were obtained. The study protocol was approved by our center's ethics committee.
CT
Pulmonary Nodules
FDG-PET
Diagnostic Algorithm
Spirometry
Data Analysis
Study Population and Risk Factors A total of 911 (74% men) subjects participated in the study. Their mean (SD) age was 54.7 (8.6) years. Their median (interquartile range) tobacco consumption was 30 (1949.5) pack-years. Asbestos exposure was reported in only one subject. Other risk factors for lung cancer, such as radon, nickel, or chromium, were not reported.
Low-Dose CT Findings
Nodule Size and Attenuation
Of the 291 individuals with noncalcified pulmonary nodules, 160 (17.6% of participants) only had nodules less than 5 mm, 98 (10.7% of participants) had at least one nodule between 5 and 10 mm (no nodules > 10 mm), and 33 (3.6% of participants) had at least one nodule of 10 mm or more (Table 2).
FDG-PET for Nodules 10 mm or Larger or Smaller (> 7 mm), Growing Nodules Twenty-four FDG-PET scans were done on 23 individuals (25 pulmonary nodules; Table 3). One individual had two FDG-PET scans (numbers 10 and 16, Table 3) for a nodule that grew from 10.5 to 14.5 mm in 7 months, and turned out to be a malignancy. The first FDG-PET was negative (false-negative), but the second showed an SUVmax of 1.6 (true-positive). Three of the nodules studied were slightly smaller than 10 mm. Two were an 8-mm nodule (number 25, malignant) seen on the first annual repeat CT (new incidence nodule) and an 8.7-mm nodule (number 23, benign) seen on the baseline study in a patient in which the sputum cytology showed moderate to severe squamous metaplasia. FDG-PET scans for these two nodules were negative (one false-negative and one true-negative). A third 8-mm nodule (number 24, malignant) was seen in a patient with an additional 10-mm nodule (number 19, benign), which prompted the FDG-PET study. Both nodules had negative FDG-PET scans (one false-negative, one true-negative), but the 8-mm nodule showed growth on follow-up CT (squamous cell carcinoma).
Altogether, 11 nodules were positive on FDG-PET, of which nine were malignant (median SUVmax, 1.8; interquartile range, 1.63.1), one was benign (SUVmax, 2.3, and necrosis on FNA with no growth on annual CT), and one was indeterminate (SUVmax, 1.2) because the patient refused further workup and was lost to follow-up. This indeterminate nodule was excluded from the analysis. Fourteen nodules were negative on FDG-PET, of which four were malignant. These four malignancies were adenocarcinomas (two of them, numbers 15 and 25 on Table 3, had bronchoalveolar features in part of the tumor) and were all diagnosed in stage IA after growth was seen on short-term follow-up CTs. The sensitivity and specificity of FDG-PET to detect malignancy were 69 (95% confidence interval, 4189) and 91% (95% confidence interval, 6399), respectively. Positive and negative predictive values were 90 (95% confidence interval, 5798) and 71% (95% confidence interval, 5285), respectively.
Lung Cancer Stages
Invasive Procedures and Surgery All patients with nonsmall cell lung cancer (prevalence and incidence) underwent surgery. Eleven of 13 (84.6%) had lobectomies and two (15.4%) had wedge resections because of chronic obstructive pulmonary disease.
Spirometry
Similar to recent reports (9, 2022), this study confirms that a low-dose spiral CTbased protocol for early detection of lung cancer is useful in leading to early stage diagnosis in a high proportion of cases and may increase the chances for cure. Furthermore, this study shows that a carefully followed multidisciplinary diagnostic algorithm that includes FDG-PET minimizes unnecessary invasive procedures for benign lesions, without resulting in missed cancers caused by false-negative PET scans. Lung cancer is one of the leading causes of death in the world. It is the most common cancer in many countries and, because most patients are diagnosed in late stages, it is also the most lethal (13). Less than 20% of individuals suffering this disease are diagnosed in stages in which curative surgery is an option (2). Survival rates for early-stage disease are quite high, approaching 80% in some series, but overall 5-year survival rates are approximately 15% (2). Five-year survival rates for patients who have already survived 2 years (conditional survival) remain significantly higher for those diagnosed in early stages, stressing the importance of early diagnosis (23). Lung cancer screening with low-dose CT has shown to be effective in diagnosing lung cancer in the early stages. In ELCAP, 89% of lung cancers detected in the prevalence phase of the trial were diagnosed in stages I and II (9). In other screening trials, the proportion of cancers diagnosed in stages I and II varies between 75 and 90% (1014). Whether this will result in a reduction in mortality from lung cancer has not been answered yet, and is being addressed in several trials underway. However, it is clear from a clinical point of view that lung cancer diagnosed and treated in early phases has a much better prognosis. Despite the fact that earlier screening trials with chest radiographs and sputum cytology failed to show a reduction in mortality, the results obtained from CT screening trials published thus far, and those presented herein, are strong enough to warrant more research in the field. One of the major concerns regarding lung cancer screening with spiral CT is the rate of false-positive tests resulting in potentially harmful workups for benign diseases. The prevalence of noncalcified nodules on baseline low-dose spiral CT in different trials ranges between 19 and 69% (9, 12, 2022). Limiting further workup to nodules of 5 mm or more has been shown to be appropriate by Henschke and coworkers (24) in a recent study reviewing diagnoses of lung cancer in a CT screening trial according to size. In a population of 2,897 participants, lung cancer was diagnosed only in individuals with nodules of at least 5 mm in diameter. Of 378 participants with the largest noncalcified nodule less than 5 mm in diameter, none was diagnosed with a malignancy. In our series, 32% of participants had noncalcified nodules of any size, but only 14% required further workup because of the presence of at least one noncalcified nodule of 5 mm or more (positive CT scans). Among this group of individuals, the majority had small nodules between 5 and 10 mm. Following these nodules with short-term follow-up CTs for detection of growth results in a low rate of invasive procedures for benign lesions. Larger nodules or nodules that show growth on follow-up CTs, all of which are more likely to be malignant, pose a more difficult problem and are more likely to result in unnecessary invasive procedures. Our findings suggest that the addition of FDG-PET to the protocol does not eliminate the risk of unnecessary invasive procedure completely, but may reduce it to a minimum. Excluding the patient with one nodule that was positive on FDG-PET but who was lost to follow-up, the specificity and positive predictive value of FDG-PET in our series was 91 and 90%, respectively. What price, in terms of invasive procedures or even surgical interventions for benign lesions, is acceptable in screening protocols remains to be seen. In this series, no surgical intervention was done for a benign lesion, but one benign lesion did undergo an FNA. The risk for complications and the anxiety generated in the workup of benign lesions has to be considered as endpoints in future studies. On the other hand, using FDG-PET, the diagnosis of cancer in 9 of 13 patients was achieved 3 months earlier than if obtained by short-term follow-up CT. The implications this might have in terms of overall prognosis are unknown. Although FDG-PET had a positive influence on the diagnostic management of 19 of 25 cases, the sensitivity and negative predictive value of FDG-PET for the diagnosis of malignant nodules in this population was 69 and 71%. The overall sensitivity of FDG-PET for the diagnosis of pulmonary malignancies greater than 1 cm is over 95% (25). However, recent studies show that for pulmonary malignant nodules of less than 1 cm in size, the sensitivity of FDG-PET is very low (26). Four malignant nodules in our series did not show any FDG uptake. Two were smaller than 1 cm (8 mm), and two only slightly larger (10.5 and 11.5 mm). Furthermore, all four false-negative nodules were adenocarcinomas and two had a nonsolid component on the CT and bronchoalveolar features on the histologic analysis (Table 3, nodule numbers 13 and 25). These characteristics (adenocarcinoma, part-solid component, and bronchoalveolar carcinoma) have all been reported by others as causes of false-negative nodules on FDG-PET scans (26). Therefore, it is the combination of FDG-PET with a short-term follow-up CT for negative studies that makes the screening algorithm useful. In addition, although the protocol calls for percutaneous FNAs of suspicious nodules (those > 10 mm or smaller nodules that grow), the results of this study support FDG-PET as a noninvasive substitute if caution in following up negative studies is taken. The optimal interval between a negative FDG-PET and a follow-up CT to detect growth remains to be determined. It may be longer that the 3-month interval selected in this protocol, thus decreasing the potential hazards caused by radiation, as well as the costs of the algorithm. SUVs may provide numeric thresholds to differentiate malignant and benign lesions, but in our series, visual assessment of FDG-PET scans classified the indeterminate noncalcified pulmonary nodules better. Visual analysis of FDG-PET scans was performed for diagnosis because it has been shown that SUV methodology is less straightforward than has often been assumed (27). Furthermore, the SUV of a lesion on FDG-PET decreases when the diameter is smaller than twice the spatial resolution of the system, which is 7 to 8 mm for our BGO scanner. In our study, if only lung nodules with an SUVmax greater than 2 would have been considered positive, FDG-PET would have contributed to establish the proper diagnosis in 14 cases instead of the 19 cases correctly diagnosed with visual analysis. The sensitivity and the negative predictive value of FDG-PET for the diagnosis of malignant nodules would have decreased to 23 and 52%, respectively. The efficiency of a screening program will depend largely on the pretest probability (prevalence) of having the disease. The higher the prevalence, the lower the risk of false-positive results. The prevalence will be higher as the inclusion of individuals in the screening program becomes more selective, focusing on higher risk. One future possibility is the use of biomarkers, not only for early detection but for risk stratification as well (28). From a clinical point of view, the presence of airways disease may be important for risk stratification. In this study, 79% of the patients with lung cancer had airflow obstruction by GOLD criteria (19). Therefore, limiting enrollment to individuals with evidence of airflow obstruction might enhance efficiency. Related to this finding is the fact that 30% of the participants showed evidence of airflow obstruction. A recent preliminary randomized controlled lung cancer screening trial, in which patients were classified according to the presence of airways disease into high-risk (airflow obstruction) and moderate-risk (no airflow obstruction) individuals, showed that the probability of finding noncalcified nodules is significantly higher (40 vs. 22%) in patients with airways obstruction (29). This also raises the issue of whether a screening program for lung cancer might be useful for screening other important diseases, such as chronic obstructive pulmonary disease, which is the fifth leading cause of death worldwide (30). This report and others point out one very important aspect. Early lung cancer detection is complex and requires a multidisciplinary approach. With the data available to date, lung cancer screening, although promising, still requires intensive research before wide implementation. But it is quite clear that the diagnosis and management of lung cancer are due for a change. The need for a new staging system that addresses smaller lung cancers is emerging. Data from Europe and the United States strongly suggest that the current size threshold for staging lung cancers (i.e., 3 cm) is not adequate and support the notion that detecting small-volume lung cancers provides a better chance for cure. The Spanish Bronchogenic Carcinoma Co-operative Group has found that classifying patients into four groups according to tumor size (02 cm, 2.14 cm, 4.17 cm, and > 7 cm) better predicted prognosis (31). In the United States, using the 2003 Surveillance, Epidemiology, and End Results, or SEER, registry, Wisnivesky and coworkers (32) showed that 12-year survival among patients with stage I lung cancer who had undergone surgical resection was inversely proportional to the initial tumor size. In conclusion, early detection of lung cancer after a carefully designed low-dose spiral CTbased protocol with the addition of FDG-PET for nodules of 10 mm or more, or for smaller (> 7 mm) growing nodules, is possible. The addition of FDG-PET to the protocol may reduce unnecessary invasive procedures to a minimum without resulting in missed cancers. This strategy may improve chances for cure because epidemiologic data strongly suggest that the prognosis of lung cancer is significantly better when diagnosed in early stages.
The authors thank Ms. Marta Moreno for her invaluable technical assistance.
This article has an online supplement, which is accessible from this issue's table of contents at www.atsjournals.org Conflict of Interest Statement: G.B. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; M.J.G.-V. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; M.D.L. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; U.M. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; W.T. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; N.S. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; A.C. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; L.S. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; A.B.A. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; J.P. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; D.C. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; I.V. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; O.C. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; P.D. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; P.S. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; J.A.R. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; L.M. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript; J.J.Z. does not have a financial relationship with a commercial entity that has an interest in the subject of this manuscript. Received in original form November 5, 2004; accepted in final form March 18, 2005
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||