help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Published ahead of print on October 4, 2002, doi:10.1164/rccm.200201-022OC
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Online Supplement
Right arrow All Versions of this Article:
200201-022OCv1
167/1/20    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Massie, C. A.
Right arrow Articles by Douglas, N. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Massie, C. A.
Right arrow Articles by Douglas, N. J.
American Journal of Respiratory and Critical Care Medicine Vol 167. pp. 20-23, (2003)
© 2003 American Thoracic Society


Original Article

Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home

Clifford A. Massie, Nigel McArdle, Robert W. Hart, Wolfgang W. Schmidt-Nowara, Alan Lankford, David W. Hudgel, Nancy Gordon and Neil J. Douglas

Suburban Lung Associates, Elk Grove Village, Illinois; University Department of Medicine, University of Western Australia, Royal Perth Hospital, Perth, Australia; Sleep Medicine Associates of Texas, Dallas, Texas; Sleep Disorders Center of Georgia, Atlanta, Georgia; Case Western Reserve University, Cleveland, Ohio; Gordon and Associates, Berkeley, California; and Department of Medicine, Royal Infirmary, Edinburgh, United Kingdom

Correspondence and requests for reprints should be addressed to Clifford A. Massie, Ph.D., Suburban Lung Associates, 810 Biesterfield Rd., Suite 404, Elk Grove Village, IL 60007. E-mail: clifford.massie{at}sublung.com


    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
We tested the hypothesis that continuous positive airway pressure (CPAP) use and outcomes can be improved by an autotitrating CPAP device in patients with obstructive sleep apnea–hypopnea syndrome (OSAHS) who require higher CPAP (10 cm H2O or more). In this multisite randomized single-blind cross-over study, 44 patients (mean age, 49 ± 10 years) were randomized to 6 weeks at laboratory-determined fixed pressure and 6 weeks on autotitrating CPAP. Average nightly use was greater in automatic mode (306 versus 271 minutes, p = 0.005); median and 95th centile pressures in automatic mode were lower (p < 0.002). Automatic CPAP resulted in better SF-36 Vitality scores (65 ± 20 versus 58 ± 23, p < 0.05) and mental health scores (80 ± 14 versus 75 ± 18, p < 0.05), but no significant difference in Epworth score (p = 0.065). During automatic therapy, patients reported more restful sleep, better quality sleep, less discomfort from pressure, and less trouble getting to sleep for both the first week of therapy and for the averaged scores for Weeks 2–6 (all p values < 0.006). Patients who require higher fixed CPAP use autotitrating CPAP more and report greater benefit from this therapy.

Key Words: adverse effects • compliance • continuous positive airway pressure • obstructive sleep apnea


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Obstructive sleep apnea–hypopnea syndrome (OSAHS) is associated with excessive daytime sleepiness, impaired quality of life, and hypertension (1, 2). Continuous positive airway pressure (CPAP) is an effective treatment for OSAHS symptoms (3, 4), and may also decrease hypertension and vascular risk (5). Rates of nightly use are suboptimal in both short-term and long-term studies, averaging 3 to 5 hours per night (6, 7). Use may be limited by side effects such as pressure intolerance, difficulty in exhaling, mask dislodgement, mask leak, and air leak through the mouth (7, 8).

Changes in weight, body position, alcohol use, or nasal patency can alter acute and chronic CPAP requirements (9, 10). The AutoSet T (ResMed, San Diego, CA) is an autoadjusting CPAP device designed to provide the minimum pressure at each time point of treatment to eliminate apneas, hypopneas, and upper airway resistance (11). Providing a lower mean pressure level during treatment may attenuate side effects associated with pressure intolerance and enhance compliance. This might benefit patients who require high CPAP levels. Studies comparing the AutoSet with fixed pressure delivery at laboratory titration have demonstrated lower median pressures with the AutoSet (12, 13). The AutoSet ameliorates sleep-disordered breathing, while preserving sleep architecture and continuity (12).

The present study assessed whether objective CPAP use, quality of life, and daytime sleepiness can be improved with the use of the AutoSet in automatic mode for patients who require higher CPAP (10 cm H2O or more) as determined by manual laboratory titration. Secondary outcome measures included self-reported sleep quality and satisfaction with CPAP use.


    METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Design
In a five-site randomized single-blind cross-over study, patients received fixed pressure and autotitrating therapy for two 6-week limbs, using the AutoSet. In automatic mode, the CPAP could range from 4 to 20 cm H2O. Fixed pressure used was determined by a board-certified sleep specialist or equivalent on the basis of minimization of apneas, hypopneas, snoring, hypoxemia, and arousals during either all-night CPAP titration or a split-night study according to American Academy of Sleep Medicine standards (14). Heated humidification was not used during the study.

Institutional review board approval was obtained from each site and written informed consent was obtained. Patients completed the Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36) (15) and the Epworth Sleepiness Scale (ESS) (16). Patients were fitted with a ResMed Mirage or alternative nasal mask, and prospectively completed a sleep diary. Patients were given detailed instructions on using the CPAP equipment. They were not informed of the type of therapy they were receiving, but were informed that compliance was being monitored.

At the second visit, each patient returned with the AutoSet machine and the sleep diary. Compliance data were downloaded from the AutoSet (AutoScan, version 3.1; ResMed) and use time was derived from the "time at pressure" data. The SF-36 and ESS were reassessed, sleep diaries were reviewed, and new diaries were issued. The AutoSet was then switched to the alternate mode and returned to the patient. At the final visit, outcomes were reassessed and patients were debriefed regarding the nature of the study and given feedback regarding use data. A stipend was given to patients who successfully completed the 12-week protocol.

Subjects
At each site, consecutive eligible patients were invited to participate in the study immediately after their overnight laboratory CPAP titration study, if it showed the need for higher CPAP (10 cm H2O or more). Other entry criteria were symptomatic OSAHS with an apnea–hypopnea index of 15 or more (17) and age between 18 and 65 years. None had received CPAP previously. Exclusion criteria included preexisting lung disease, awake resting SaO2 < 90%, or 10 or more central apnea–hypopnea events per hour; patients were also excluded if they were taking medications known to significantly interfere with sleep or respiration.

Questionnaires
Patients completed the SF-36, a general quality of life survey designed to assess a patient's perception of his or her health status. The SF-36 has been used extensively, including in sleep apnea (18), and its reliability and validity are documented (19). The ESS is a self-administered questionnaire that measures a patient's subjective sleepiness (16). Patients completed, daily for the first week, and then weekly thereafter, a sleep diary comprising 12 sleep-related questions rated on 100-mm visual analog scales (Table 1) . A mean value was calculated for the first week of each treatment and for Weeks 2–6.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Sleep diary questionnaire

 
Statistical Analyses
Values are given as means ± standard deviation. Comparisons between treatments were performed by two-way analysis of variance with treatment order as a between-subjects factor and treatment type as a within-subjects factor for normally distributed data and by Wilcoxon tests for nonnormally distributed data.


    RESULTS
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Patient Characteristics
Forty-six patients were enrolled in the study. One patient dropped out at the end of the first limb because he did not wish to continue with CPAP therapy, and another patient's CPAP machine did not provide compliance data. Three patients had fixed pressures decreased from 10, 14, and 11 cm H2O to 8, 8, and 9 cm H2O, respectively, after beginning the fixed pressure limb because of pressure intolerance. Forty-four patients (36 men and 8 women) completed the 12-week protocol and their data are reported. Their mean age was 49 ± 10 years, with a mean body mass index of 32 ± 4 kg/m2.

CPAP Use Data
Patients used the AutoSet in automatic mode an average of 35 minutes more per night compared with the fixed mode (p = 0.005; Table 2) . During automatic therapy lower median and 95th centile pressures were delivered (both p values < 0.001). Neither the percentage of nights that CPAP was used nor the apnea–hypopnea index differed significantly between fixed mode and automatic mode (Table 2).


View this table:
[in this window]
[in a new window]
 
TABLE 2. Continuous positive airway pressure use data

 
Quality of Life Questionnaires
Automatic CPAP resulted in significantly (p < 0.05) better SF-36 Vitality scores (65 ± 20 versus 58 ± 23) and SF-36 Mental Health scores (80 ± 14 versus 75 ± 18) than fixed pressure CPAP. There were no differences between treatment type in the outcomes on the other six SF-36 domains: Physical Function, Role-physical, Bodily Pain, General Health, Social Function, and Role-emotional (all p values > 0.07). There was only a trend to improvement of ESS scores among patients receiving automatic pressure (automatic mode, 8 ± 4; fixed mode, 9 ± 4).

Sleep Diary
During automatic therapy, patients reported (all p values < 0.006) more restful sleep, overall better sleep quality, less discomfort from pressure, and less trouble getting to sleep for the first week of therapy; the same results were obtained for Weeks 2–6 for averaged scores. All sleep diary comparisons are presented in Table E1 (see the online data supplement).


    DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
This study found that patients who require higher CPAP (10 cm H2O or more on manual laboratory titration) have greater nightly CPAP use with autotitrating CPAP compared with fixed pressure CPAP. Average autotitrating CPAP levels were lower than fixed pressure CPAP levels, as determined by manual laboratory titration. Autotitrating CPAP was associated with improvements in SF-36 Vitality and Mental Health scores, but no significant improvement in Epworth score. Sleep diary questions showed improvement with automatic therapy, such as less discomfort from pressure, improved sleep quality, more restful sleep, and less trouble getting to sleep.

In this study the ESS score did not improve when SF-36 Vitality, another measure weighted to sleepiness, did improve. The SF-36 Vitality scale may be a more sensitive marker of improvement in OSAHS with treatment than the ESS. Other studies have shown large effect sizes for this measure after CPAP treatment (4). Patients reported better sleep quality and fewer problems with CPAP use during automatic therapy. Sleep diary questions were chosen for their pertinence to CPAP outcome, use in prior studies, and face validity. However, the sleep diary questionnaire was not validated, which limits the generalizability of these results.

The goal of laboratory titration is to determine the minimum pressure required to normalize sleep-disordered breathing and hypoxemia, which must include the higher pressures usually observed during supine rapid eye movement sleep. Patients who require higher fixed pressure levels during laboratory titration may require high pressure levels for only a small percentage of sleep (13). The data regarding an association between pressure level, use, and side effects are equivocal. Some studies have shown decreased CPAP use with higher pressures (20), but most studies have failed to demonstrate a reduction in CPAP use or a higher incidence of side effects with increasing CPAP (2123). All of these studies included a broad range of CPAP levels, and did not examine patients who required higher fixed pressures. Few long-term studies of pressure requirements have been performed. Studies with follow-up intervals of 2 to 9 months have failed to demonstrate significant differences in fixed pressure requirements (24, 25), while mean autotitrating CPAP values remained lower than original laboratory fixed pressure determinations (25). Other studies have demonstrated reductions in mean CPAP levels after 2 weeks of treatment (26) and during longer follow-up intervals (27).

Studies comparing the effects of autotitrating CPAP devices with fixed pressure CPAP have consistently found that autotitrating CPAP is as effective at controlling sleep-disordered breathing as fixed pressure CPAP (25, 2832). Whether there is any extra benefit associated with using autotitrating CPAP is less clear. A few studies have shown improved sleep architecture when using autotitrating CPAP (28, 29) and all but one study (31) found that pressure requirements are lower with autotitrating CPAP compared with fixed pressure CPAP (25, 28, 30, 32, 33). There have been previous suggestions of clinical benefit with the use of auto-CPAP in comparison with the fixed pressure device. In one study, the number of hours per night that positive pressure was applied favored autotitrating CPAP (30), and in another study 75% of patients preferred autotitrating therapy (32). However, in this latter study, as in others, no compliance differences were found between autotitrating and fixed pressure therapy (28, 33). The current study found greater autotitrating CPAP use at effective pressure and extends previous studies by showing that autotitrating CPAP use can improve some quality of life domains. It is postulated that selecting patients who require higher fixed CPAP also selects those who will gain the most clinical benefit, but whether this will be a consistent finding is still unknown. Another aspect is that intelligent CPAP machines perform differently (34). The response to sleep breathing patterns is different among automatic CPAP devices, and therefore results from one machine are not generalizable to others.

Patterns of CPAP use are established early in treatment and therefore optimizing CPAP use is paramount. Studies have shown that increased nightly use in the first 1–3 months predicts longer term use (6, 7). Intensive education and support result in improvements in CPAP use, but these interventions can be labor and cost intensive (35). Other interventions that enhance CPAP use are the addition of heated humidity at CPAP initiation (36). Compliance gains with heated humidity were similar in magnitude to those in the present study. Heated humidification reduced side effects related to nasal pathology, but no differences were noted on ESS scores. This is similar to the present investigation; fewer adverse effects, improvements in sleep quality, and energy level (SF-36 Vitality) likely resulted in greater AutoSet use in the automatic mode. However, ESS scores were not improved with autotitrating therapy. Autotitrating CPAP has an advantage over heated humidification in terms of convenience as the humidifier does not need to be cleaned and replenished nightly, while autotitrating CPAP and standard CPAP plus heated humidification may be similar in price.

Quality of life and cognitive functioning are impaired in patients with OSAHS, with degree of impairment being related to OSAHS severity (1). Improvements in quality of life have been observed on SF-36 Physical and Mental Health scales after treatment with CPAP (3739). Reductions in daytime sleepiness and improved cognitive functioning have been observed with as little as 4 hours of CPAP use per night (40). Furthermore, amount of CPAP use per night is positively correlated with reductions in ESS scores and increased sleep latencies on the Maintenance of Wakefulness Test (41). The question is raised: can further improvements in quality of life be attained by a specific type of CPAP intervention? The current investigation supports this assumption. Autotitrating CPAP resulted in differential improvements in quality of life measures compared with fixed pressure CPAP. As would be anticipated, the quality of life differences between the two forms of active treatment were not as large compared with the differences between CPAP treatment and no therapy. Increased objective use and a reduction in CPAP-specific adverse effects with autotitrating CPAP may be responsible for the greater improvements in quality of life observed, as the apnea–hypopnea index during the time treated was the same with both forms of CPAP.

Limitations of this study include the single-blind study design and the relatively short assessment interval. The study was performed in a single-blind fashion because some investigators had to be involved in the mode settings of the devices. The investigators could have influenced CPAP use by their enthusiasm (knowingly or unknowingly) for the automatic mode of treatment, but were instructed not to convey any bias. Care was taken to ensure that all end points were either objective and unalterably determined by the recording devices or were scored only by the patient, such as visual analog scales and Epworth Sleepiness Scale. In addition, all end points were reviewed by the study monitor. Thus, the investigators had no opportunity to directly influence the results. As the study was performed as a cross-over design, patients could theoretically detect the difference between the modes of the device. Patients were blinded to the mode of the device and the hypothesis under test and all were naive to CPAP therapy; thus we do not believe this would have influenced the results. The intervention time of 6 weeks in this study was relatively short. Longer term studies are needed to determine whether benefits in compliance and quality of life are maintained. The ability to compensate for changes in pressure requirements, both acutely and chronically, accompanied by lower mean pressures, may result in long-term gains in CPAP use. Also, this study does not generalize to all patients prescribed CPAP, as patients were selected on the basis of higher CPAP requirements. Mean pressure levels across all patients prescribed CPAP is in the range of 9–10 cm H2O, and therefore patients in this study are from the top 50% of the distribution. Whether all patients would demonstrate compliance gains with the AutoSet is not yet known.

We conclude that among patients requiring higher CPAP (10 cm H2O or more) there are improvements in CPAP use, OSAHS symptoms, and quality of life domains when using autotitrating as opposed to fixed pressure CPAP.


    Acknowledgments
 
The authors thank Robyn Longford, R.N., RPSGT, of ResMed Corporation, for assistance in coordinating this multisite study. Neil Douglas is a medical advisor to ResMed.


    FOOTNOTES
 
Supported by a grant from ResMed Corporation.

This article has an online supplement, which is accessible from this issue's table of contents online at www.atsjournals.org

Received in original form October 9, 2001; accepted in final form September 23, 2002


    REFERENCES
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 

  1. Baldwin CM, Griffith KA, Nieto FJ, O'Connor GT, Walsleben JA, Redline S. The association of sleep-disordered breathing and sleep symptoms with quality of life in the Sleep Heart Health Study. Sleep 2001;24:96–105.[Medline]
  2. Hla KM, Young TB, Bidwell T, Palta M, Skatrud JB, Dempsey J. Sleep apnea and hypertension: a population-based study. Ann Intern Med 1994;120:382–388.[Abstract/Free Full Text]
  3. Engleman HM, Kingshott RN, Martin SE, Douglas NJ. Cognitive function in the sleep apnea/hypopnea syndrome (SAHS). Sleep 2000;23:S102–S108.
  4. Jenkinson C, Davies RJ, Mullins R, Stradling JR. Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnea: a randomized prospective parallel trial. Lancet 1999;353:2100–2105.[CrossRef][Medline]
  5. Faccenda JF, Mackay TW, Boon NA, Douglas NJ. Randomized placebo-controlled trial of continuous positive airway pressure on blood pressure in the sleep apnea–hypopnea syndrome. Am J Respir Crit Care Med 2001;163:344–348.[Abstract/Free Full Text]
  6. McArdle N, Devereux G, Heidarnejad H, Engleman HM, Mackay TW, Douglas NJ. Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 1999;159:1108–1114.[Abstract/Free Full Text]
  7. Kribbs NB, Pack AI, Kline LR, Smith PL, Schwartz AR, Schubert NM, Redline S, Henry JN, Getsy JE, Dinges DF. Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis 1993;147:887–895.[Medline]
  8. Kalan A, Kenyon GS, Seemungal TA, Wedzicha JA. Adverse effects of nasal continuous airway pressure therapy in sleep apnoea syndrome. J Laryngol Otol 1999;113:888–892.[Medline]
  9. McNicholas WT, Tarlo S, Cole P, Zamel N, Rutherford R, Griffin D, Phillipson EA. Obstructive apneas during sleep in patients with seasonal allergic rhinitis. Am Rev Respir Dis 1982;126:625–628.[Medline]
  10. Mitler M, Dawson A, Henriksen SJ, Sobers M, Bloom FE. Bedtime ethanol increases resistance of upper airways and produces sleep apneas in asymptomatic snorers. Alcohol Clin Exp Res 1988;12:801–805.[CrossRef][Medline]
  11. Berthon-Jones M. Feasibility of a self-setting CPAP machine. Sleep 1993;16:S120–S123.[Medline]
  12. Teschler H, Berthon-Jones M, Thompson AB, Henkel A, Henry J, Konietzko N. Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome. Am J Respir Crit Care Med 1996;154:734–740.[Abstract]
  13. Berthon-Jones M, Lawrence S, Sullivan CE, Grunstein R. Nasal continuous positive airway pressure treatment: current realities and future. Sleep 1996;19:S131–S135.[Medline]
  14. American Sleep Disorders Association. American Sleep Disorders Association report: practice parameters for the indications for polysomnography and related procedures. Sleep 1997;20:406–422.[Medline]
  15. Ware JE Jr, Sherbourne CD. The MOS 36-Item Short-Form Health Survey (SF-36). I. Conceptual framework and item selection. Med Care 1992;30:473–483.[Medline]
  16. Johns MW. A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep 1991;14:540–545.[Medline]
  17. American Academy of Sleep Medicine Task Force. Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. Sleep 1999;22:667–689.[Medline]
  18. Baldwin CM, Griffith KA, Nieto J, O'Connor GT, Walsleben JA, Redline S. The association of sleep-disordered breathing and sleep symptoms with quality of life in the Sleep Heart Health Study. Sleep 2001;24:96–105.
  19. McHorney CA, Ware JE Jr, Lu JF, Sherbourne CD. The MOS 36-Item Short-Form Health Survey (SF-36). III. Tests of data quality, scaling assumptions, and reliability across diverse patient groups. Med Care 1994;32:40–66.[Medline]
  20. Series F, Marc I, Cormier Y, La Forge J. Required levels of nasal continuous positive airway pressure during treatment of obstructive sleep apnea. Eur Respir J 1994;7:1776–1781.[Abstract]
  21. Collard P, Pieters T, Aubert G, Delguste P, Rodenstein DO. Compliance with nasal CPAP in obstructive sleep apnea patients. Sleep Med Rev 1997;1:33–44.[CrossRef][Medline]
  22. Reeves-Hoche MK, Meck R, Zwillich CW. Nasal CPAP: an objective evaluation of patient compliance. Am J Respir Crit Care Med 1994;149:149–154.[Abstract]
  23. Hoffstein V, Viner S, Mateika S, Conway J. Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Am Rev Respir Dis 1992;145:841–845.[Medline]
  24. Grote L, Hedner J, Grunstein R, Kraiczi H. Therapy with nCPAP: incomplete elimination of sleep related breathing disorder. Eur Respir J 2000;16:921–927.[Abstract]
  25. Teschler H, Wessendorf TE, Farhat AA, Konietkzo N, Berthon-Jones M. Two months auto-adjusting versus conventional nCPAP for obstructive sleep apnoea syndrome. Eur Respir J 2000;15:990–995.[Abstract]
  26. Jokic R, Klimaszewski A, Sridhar G, Fitzpatrick MF. Continuous positive airway pressure requirement during the first month of treatment in patients with severe obstructive sleep apnea. Chest 1998;114:1061–1069.[Abstract/Free Full Text]
  27. Series F, Marc I, Cormier Y, La Forge J. Required levels of nasal continuous positive airway pressure during treatment of obstructive sleep apnea. Eur Respir J 1994;7:1776–1781.
  28. Konermann M, Sanner BM, Vyleta M, Laschewski F, Groetz J, Sturm A, Zidek W. Use of conventional and self-adjusting nasal continuous positive airway pressure for treatment of severe obstructive sleep apnea syndrome: a comparative study. Chest 1998;113:714–718.[Abstract/Free Full Text]
  29. Scharf MB, Brannen DE, McDannold MD, Berkowitz DV. Computerized adjustable versus fixed nCPAP treatment of obstructive sleep apnea. Sleep 1996;19:491–496.[Medline]
  30. Meurice JC, Marc I, Series F. Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 1996;153:794–798.[Abstract]
  31. Ficker JH, Wiest GH, Lehnert G, Wiest B, Hahn EG. Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea. Thorax 1998;53:643–648.[Abstract/Free Full Text]
  32. Randerath WJ, Schraeder O, Galetke W, Feldmeyer F, Ruhle KH. Autoadjusting CPAP therapy based on impedance efficacy, compliance and acceptance. Am J Respir Crit Care Med 2001;163:652–657.[Abstract/Free Full Text]
  33. Hudgel DW, Fung C. A long-term randomized, cross-over comparison of auto-titrating and standard nasal continuous airway pressure. Sleep 2000;23:645–648.[Medline]
  34. Farre R, Montserrat JM, Rigau J, Trepat X, Pinto P, Navajas D. Response of automatic continuous positive airway pressure devices to different sleep breathing patterns: a bench study. Am J Respir Crit Care Med 2002;166:469–473.[Abstract/Free Full Text]
  35. Hoy CJ, Vennelle M, Kingshott RN, Engleman HM, Douglas NJ. Can intensive support improve continuous positive airway pressure use in patients with the sleep apnea/hypopnea syndrome? Am J Respir Crit Care Med 1999;159:1096–1100.[Abstract/Free Full Text]
  36. Massie CA, Hart RW, Peralez K, Richards GN. Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure. Chest 1999;116:403–408.[Abstract/Free Full Text]
  37. D'Ambrosio C, Bowman T, Mohsenin V. Quality of life in patients with obstructive sleep apnea: effect of nasal continuous positive airway pressure: a prospective study. Chest 1999;115:123–129.[Abstract/Free Full Text]
  38. Bennett LS, Barbour C, Langford B, Stradling JR, Davies RJO. Health status in obstructive sleep apnea. Am J Respir Crit Care Med 1999;159:1884–1890.[Abstract/Free Full Text]
  39. Montserrat JM, Ferrer M, Hernandez L, Farre R, Vilagut G, Navajas D, Badia JR, Carrasco E, de Pablo J, Ballester E. Effectiveness of CPAP treatment in daytime function in sleep apnea syndrome: a randomized controlled study with an optimized placebo. Am J Respir Crit Care Med 2001;164:608–613.[Abstract/Free Full Text]
  40. Engleman HM, Martin SE, Deary IJ, Douglas NJ. Effect of continuous positive airway pressure treatment on daytime function in sleep apnoea/hypopnoea syndrome. Lancet 1994;343:572–575.[CrossRef][Medline]
  41. Stradling JR, Davies RJ. Is more NCPAP better? Sleep 2000;23:S150–S153.



This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
N. A. Antic, C. Buchan, A. Esterman, M. Hensley, M. T. Naughton, S. Rowland, B. Williamson, S. Windler, S. Eckermann, and R. D. McEvoy
A Randomized Controlled Trial of Nurse-led Care for Symptomatic Moderate-Severe Obstructive Sleep Apnea
Am. J. Respir. Crit. Care Med., March 15, 2009; 179(6): 501 - 508.
[Abstract] [Full Text] [PDF]


Home page
ACCP Sleep Med Brd RevHome page
N. S. Freedman
Positive Airway Pressure Therapy for Obstructive Sleep Apnea Syndrome: The Boards and Beyond
ACCP Sleep Med Brd Rev, January 1, 2009; 4(0): 293 - 312.
[Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
T. E. Weaver and R. R. Grunstein
Adherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Proceedings of the ATS, February 15, 2008; 5(2): 173 - 178.
[Abstract] [Full Text] [PDF]


Home page
ERRHome page
D. Pevernagie, J. F. Masa, J. C. Meurice, R. Farre, O. Marrone, and D. Rodenstein
Treatment of obstructive sleep-disordered breathing with positive airway pressure systems
Eur. Respir. Rev., December 1, 2007; 16(106): 125 - 131.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. A. Smith, M. Vennelle, R. S. Gardner, T. A. McDonagh, M. A. Denvir, N. J. Douglas, and D. E. Newby
Auto-titrating continuous positive airway pressure therapy in patients with chronic heart failure and obstructive sleep apnoea: a randomized placebo-controlled trial
Eur. Heart J., May 2, 2007; 28(10): 1221 - 1227.
[Abstract] [Full Text] [PDF]


Home page
J. Neurol. Neurosurg. PsychiatryHome page
C-Y Hsu, M Vennelle, H-Y Li, H M Engleman, M S Dennis, and N J Douglas
Sleep-disordered breathing after stroke: a randomised controlled trial of continuous positive airway pressure
J. Neurol. Neurosurg. Psychiatry, October 1, 2006; 77(10): 1143 - 1149.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. Rigau, J. M. Montserrat, H. Wohrle, D. Plattner, M. Schwaibold, D. Navajas, and R. Farre
Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
Chest, August 1, 2006; 130(2): 350 - 361.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. M. Nolan, S. Ryan, T. M. O'Connor, and W. T. McNicholas
Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea
Eur. Respir. J., July 1, 2006; 28(1): 159 - 164.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. A. Arias, F. Garcia-Rio, A. Alonso-Fernandez, I. Martinez, and J. Villamor
Pulmonary hypertension in obstructive sleep apnoea: effects of continuous positive airway pressure: A randomized, controlled cross-over study
Eur. Heart J., May 1, 2006; 27(9): 1106 - 1113.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
Y. Nussbaumer, K. E. Bloch, T. Genser, and R. Thurnheer
Equivalence of Autoadjusted and Constant Continuous Positive Airway Pressure in Home Treatment of Sleep Apnea
Chest, March 1, 2006; 129(3): 638 - 643.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
S D West, D R Jones, and J R Stradling
Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea
Thorax, March 1, 2006; 61(3): 226 - 231.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. A. Arias, F. Garcia-Rio, A. Alonso-Fernandez, O. Mediano, I. Martinez, and J. Villamor
Obstructive Sleep Apnea Syndrome Affects Left Ventricular Diastolic Function: Effects of Nasal Continuous Positive Airway Pressure in Men
Circulation, July 19, 2005; 112(3): 375 - 383.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
L. Luthje, C. Unterberg-Buchwald, D. Dajani, D. Vollmann, G. Hasenfuss, and S. Andreas
Atrial Overdrive Pacing in Patients with Sleep Apnea with Implanted Pacemaker
Am. J. Respir. Crit. Care Med., July 1, 2005; 172(1): 118 - 122.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. S. Aloia, M. Stanchina, J. T. Arnedt, A. Malhotra, and R. P. Millman
Treatment Adherence and Outcomes in Flexible vs Standard Continuous Positive Airway Pressure Therapy
Chest, June 1, 2005; 127(6): 2085 - 2093.
[Abstract] [Full Text] [PDF]


Home page
Br Med BullHome page
G.J. Gibson
Obstructive sleep apnoea syndrome: underestimated and undertreated
Br. Med. Bull., March 29, 2005; 72(1): 49 - 65.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
C. A. Hukins
Arbitrary-Pressure Continuous Positive Airway Pressure for Obstructive Sleep Apnea Syndrome
Am. J. Respir. Crit. Care Med., March 1, 2005; 171(5): 500 - 505.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
F. Abdenbi, B. Chambille, and P. Escourrou
Bench testing of auto-adjusting positive airway pressure devices
Eur. Respir. J., October 1, 2004; 24(4): 649 - 658.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. Tobin
Sleep-Disordered Breathing, Control of Breathing, Respiratory Muscles, Pulmonary Function Testing in AJRCCM 2003
Am. J. Respir. Crit. Care Med., January 15, 2004; 169(2): 254 - 264.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Online Supplement
Right arrow All Versions of this Article:
200201-022OCv1
167/1/20    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Massie, C. A.
Right arrow Articles by Douglas, N. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Massie, C. A.
Right arrow Articles by Douglas, N. J.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 2003 American Thoracic Society