help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Deykin, A.
Right arrow Articles by Israel, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Deykin, A.
Right arrow Articles by Israel, E.
American Journal of Respiratory and Critical Care Medicine Vol 165. pp. 1597-1601, (2002)
© 2002 American Thoracic Society


Original Article

Exhaled Nitric Oxide as a Diagnostic Test for Asthma

Online versus Offline Techniques and Effect of Flow Rate

Aaron Deykin, Anthony F. Massaro, Jeffrey M. Drazen and Elliot Israel

Pulmonary and Critical Care Division, Department of Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts

Correspondence and requests for reprints should be addressed to Aaron Deykin, M.D., Pulmonary Division, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115. E-mail: adeykin{at}partners.org


    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Measurement of the fraction of exhaled nitric oxide (FENO) has been proposed as a noninvasive assessment of asthmatic airway inflammation. The influence of the expiratory flow rate during the collection maneuver on the ability of FENO to discriminate healthy subjects from those with asthma is unknown. We compared online and offline measurement of FENO at different flow rates. FENO was collected with expiratory flows of 50–500 ml/second in 34 patients with asthma (PC20 of less than 8 mg/ml) and 28 healthy subjects (PC20 of more than 10 mg/ml) using offline collection techniques. In a subgroup of 18 individuals with asthma and 17 healthy subjects, we additionally measured FENO at multiple expiratory flow rates (47–250 ml/second) using online methods. FENO fell with an increasing expiratory flow rate; FENO was higher in subjects with asthma as compared with healthy subjects at each flow rate studied with both techniques (p < 0.001). Receiver operating characteristic (ROC) curves for the diagnosis of asthma indicated that FENO is a robust discriminator between individuals with asthma and healthy subjects (area under the ROC curves 0.79 ± 0.06 to 0.86 ± 0.06, p for significant discrimination < 0.0001). Neither expiratory flow rate nor collection technique (online versus offline) significantly altered this discriminatory capacity (area under the ROC curves = 0.84 ± 0.07 with the slowest online method versus 0.80 ± 0.07 with the fastest offline method, p = 0.46). These data indicate that the choice of expiratory flow rate and collection method can be based on practicality and patient comfort without compromising the utility of this test for asthma.

Key Words: nitric oxide • asthma • diagnosis


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
In comparison to normal individuals, the fraction of exhaled nitric oxide (FENO) is elevated in subjects with asthma, and these elevated levels have been shown to vary with disease activity and in response to antiinflammatory therapy (15). These observations have prompted several authors to suggest that FENO may be a noninvasive marker of asthmatic airway inflammation (1, 68). In this regard, Chatkin and colleagues have previously demonstrated in a population of subjects with chronic cough that FENO discriminated well between those with and those without asthma (9).

Many technical factors influence measured FENO values, including method of collection (offline reservoir bag or online), time of day, and expiratory flow rate. Among these, expiratory flow rate had been demonstrated to have the most dramatic effect, with FENO declining with an increasing expiratory flow rate. Furthermore, collection techniques that use slow expiratory flow rates produce NO higher values and larger part per billion differences between normal and individuals with asthma (1013). It has therefore been proposed that these low-flow methods will allow for greater discrimination between health and disease (12, 14). In addition, as standard offline measurements comprise the entire expirate (including dead space gas), do not allow for the real-time monitoring of the exhalation and exclusion of technically poor maneuvers, and are potentially subject to contamination through leaks in the collection bag, they have been considered a second choice to online measurements (15). However, slow online collection maneuvers may be uncomfortable for some subjects (16), and offline collection techniques allow for remote collection (i.e., in several clinics) with centralized use of a single analyzer greatly expanding the potential use of this new measurement. We conducted a systematic investigation of the effects of collection technique (online versus offline) and flow rates on the ability of exhaled NO to discriminate between individuals with and without asthma. In this study, we quantified and compared the ability of exhaled NO measured offline at several expiratory flow rates to distinguish individuals with asthma from healthy subjects and compared it with online measurements made at similar flow rates.


    METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Subjects
Adult nonsmokers with and without asthma were enrolled. Subjects with asthma had a history of asthma (17), with either a 12% improvement in FEV1 after inhalation of a ß agonist or a methacholine PC20 of 8 mg/ml or less. These individuals were using no asthma medications except for short-acting bronchodilators, which were withheld for at least 8 hours before all testing. No systemic or inhaled corticosteroids had been used within 8 weeks of enrollment. Healthy (without asthma) subjects had no history of asthma, normal spirometry, and a methacholine PC20 more than 8 mg/ml. All subjects had been free of upper respiratory infection for at least 6 weeks. The study protocol was approved by the Human Research Committee at the Brigham and Women's Hospital. All subjects gave their written informed consent.

Protocol
The study comprised a single visit during which subjects provided exhaled gas for NO determinations at several expiratory flow rates using offline techniques as described later here. A subgroup, approximately half of the full study population, additionally provided exhaled gas for online measurements as described later here. In all cases, the order of expiratory flow rates used and the order of measurement technique (online versus offline) were randomly determined to avoid an ordinal effect. As spirometry has been associated with alterations in FENO, no FVC maneuvers were performed within 24 hours of the study visit (1820).

Offline NO Collection and Analysis
The technical aspects of the offline collection have been described previously and are consistent with those specified in the recommendations of the American Thoracic Society (21, 22). Target flows at 10 mm Hg pressure through the system were verified by a flow and pressure calibration analyzer (model RT-200; Timeter Instruments, Lancaster, PA). Collections were made at 50, 100, 200, 350, and 500 ml/second in triplicate. The NO concentration in the Mylar bag was measured using a chemiluminescence analyzer (model 280; Sievers, Boulder, CO) within 12 hours of collection. The median value at each flow rate was reported.

Online NO Collection and Analysis
Online measurements were performed according to ATS recommendations with the exception of the variation in expiratory flow, as described later here, using a NOA 280 (Sievers) (22). While standing, subjects inhaled to TLC from a source of NO-free air and then exhaled into the analyzer mouthpiece attached to a one-way valve. Expiratory resistance was provided by needles of varying caliber attached to the expiratory limb of the apparatus (Sievers restricted breath kit; Sievers). At a pressure of 10 mm Hg, the flow through the system was 43, 108, 210, and 250 ml/second.

Statistics
Differences in data obtained from the same subjects were analyzed by two-tailed paired t tests (for normally distributed data) or by the Wilcoxon signed-ranks test (for nonnormally distributed data). Differences between subjects with asthma and healthy subjects were analyzed by two-tailed t tests (for normally distributed data) or by the Mann-Whitney U test (for nonnormally distributed data). Areas under the receiver operating characteristic (ROC) curves were compared using the Hanley and McNeil method (23). Construction of the ROC curves and all statistical tests were performed using Analyze-it, version 1.61 (Analyze-it, Inc., Leeds, UK).


    RESULTS
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Subjects
Sixty-two subjects were recruited. This study population comprised 34 individuals with asthma and 28 healthy individuals. The demographic, baseline lung function, and airway response data from these subjects are presented in Table 1.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Baseline characteristics of the study subjects

 
Offline Measurements
Effect of flow rate
All 34 individuals with asthma and 28 healthy subjects performed exhaled gas collections for offline NO determinations at five expiratory flow rates as described. At each flow rate, individuals with asthma had higher FENO values (in part per billion ± SEM) as compared with healthy subjects: 57.9 ± 6.5 versus 26.3 ± 2.2; 34.9 ± 3.7 versus 16.7 ± 1.3; 23.0 ± 2.5 versus 11.4 ± 0.9; 17.5 ± 1.7 versus 8.8 ± 0.7; and 14.0 ± 1.2 versus 7.5 ± 0.6 at 50, 100, 200, 350, and 500 ml/second, respectively (p < 0.001 for comparisons at each flow rate, Figure 1) . Offline FENO values fell with increasing flow rate; the mean FENO values at 100, 200, 350, and 500 ml/second were significantly lower that those at the next lowest flow rate for both subjects with asthma and normal subjects (p < 0.0001, Figure 1).



View larger version (15K):
[in this window]
[in a new window]
 
Figure 1. Effect of flow rate and collection techniques on measured FENO in healthy subjects (n = 34) and subjects with asthma (n = 28). In all subjects, FENO fell with an increasing flow rate. FENO was lower at each measured flow in comparison to the next lowest rate (p < 0.001 for all comparisons with the exception of online 210 versus 250 ml/s, p = 0.58 and 0.27 for healthy subjects and subjects with asthma, respectively). At each rate and with both collection techniques, FENO was higher in subjects with asthma as compared with healthy subjects (p < 0.001).

 
ROC analysis
ROC curves were constructed by plotting the sensitivity of offline FENO as a diagnostic test for asthma versus 1-specificity at each flow rate. The area under the ROC curves (AUCs), a measure of diagnostic power, ranged from 0.78 ± 0.06 to 0.82 ± 0.06. The discrimination between subjects with asthma and healthy subjects was robust at all flow rates (p < 0.0001, Table 2). This robust discriminatory power between individuals with asthma and healthy individuals was similar at low offline flow rates as compared with that at intermediate and higher offline expiratory flow rates (p > 0.43 for all comparisons).


View this table:
[in this window]
[in a new window]
 
TABLE 2. Rocs of fEno as a test for asthma using online and offline techniques at multiple expiratory flow rates

 
Online Measurements
Effect of flow rate
A subgroup of 18 subjects with asthma and 17 healthy subjects performed additional exhaled gas collections for online NO determinations at four expiratory flow rates as described. Similar to the offline measurements, individuals with asthma had higher mean FENO values (in part per billion ± SEM) at each flow rate as compared with healthy subjects: 59.7 ± 8.6 versus 25.8 ± 2.6; 25.7 ± 3.4 versus 12.6 ± 1.2; 16.4 ± 1.9 versus 8.7 ± 0.6; 16.0 ± 2.0 versus 8.4 ± 0.7 at 42, 110, 210, and 250 ml/second, respectively (p < 0.001 for comparisons at each flow rate, Figure 1). Online FENO values fell with increasing expiratory flow rate. The mean FENO values at 108 and 210 ml/second were significantly lower than those at the next lowest flow rate for both subjects with asthma and healthy subjects (p < 0.0001). The smaller increase in flow from 210 to 250 ml/second did not produce significant changes in mean FENO values in individuals with asthma and normal individuals (p = 0.58 and p = 0.27, respectively, Figure 1).

ROC analysis
ROC curves constructed for online measurements demonstrated that the AUC was similar at low flow rates as compared with that at intermediate and higher flow expiratory flow rates (Table 2). The AUC ranged from 0.82 ± 0.07 to 0.86 ± 0.06 (p for discrimination < 0.0001 at all flow rates, Table 2). The discrimination between individuals with asthma and healthy individuals was similar at low online flow rates as compared with that at intermediate and higher online expiratory flow rates. The AUC was 0.84 ± 0.07 at 42 ml/second, as compared with 0.86 ± 0.6 and 0.83 ± 0.07 at 108 and 250 ml/second, respectively (p > 0.05).

Offline versus online comparisons
To examine the diagnostic capability of offline FENO measurements for asthma in comparison to online measurements at multiple flow rates, ROC curves generated from online and offline measurements in the same subjects were compared. At similar flow rates, the AUC derived from offline measurements was not statistically different from that derived from online measurements (p = 0.25–0.98, Figure 2) . No combined effect of measurement technique and flow rate was noted. To exclude the possibility that subtle differences in discriminatory power between online and offline techniques could be magnified by extremes of flow, we compared the AUC derived from the fastest offline measurements with that obtained from the slowest online measurements and found no difference (0.80 ± 0.06 versus 0.84 ± 0.07, p = 0.45, Figure 3) .



View larger version (16K):
[in this window]
[in a new window]
 
Figure 2. ROC curves for FENO collected using online (solid line) and offline (dashed line) techniques. Over the range of flows specified in current ATS guidelines (low flow, 50 ml/s; medium flow, 100 ml/s; and high flow, 200 ml/s), the two techniques had a similar ability to discriminate healthy subjects from those with asthma (p = 0.25–0.98).

 


View larger version (22K):
[in this window]
[in a new window]
 
Figure 3. ROC curves for FENO collected using a slow exhalation online (solid line) and fast exhalation offline (dashed line) technique. The discriminatory power of the slowest online technique was not different from that of the fastest offline technique (p = 0.45).

 
Sensitivity, specificity, and positive and negative predictive values for FENO as a diagnostic test for asthma, at a cutoff of 1.96 SE above the mean healthy FENO value at each of the flow rates, are presented in Table 3. The sensitivity and specificity for a diagnosis of asthma were generally 70% or greater for both techniques and all flow rates. The positive and negative predictive values are calculated using both the prevalence of asthma in the study group (0.55) and in the general population (0.05). These measures of diagnostic power were generally similar using both online and offline collections over the range of flow rates studied.


View this table:
[in this window]
[in a new window]
 
TABLE 3. Performance characteristics of fEno as a test for asthma

 

    DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
FENO is characteristically elevated in asthma and has been demonstrated to distinguish individuals without asthma from individuals with asthma in several reports (1, 9, 24, 25). However, controversy exists regarding which flow rate and measurement technique should be used to distinguish optimally patients with asthma from healthy subjects (1215, 22, 26). In this study, we investigated the effect of expiratory flow rate and measurement technique on the ability of FENO to detect subjects with and without asthma in a well-characterized study population. We found that the diagnostic power of FENO for asthma is not influenced by either the expiratory flow rate across the range of flows in current use or by measurement technique (online or offline).

To examine the influence of flow rate and collection method on the ability of FENO to discriminate between subjects with asthma and healthy subjects, we constructed ROC curves for a diagnosis of asthma and then compared the AUC constructed using the data obtained from these subjects at multiple flow rates using online and offline methods. ROC curves plot the sensitivity (true positive rate) of a test against 1-specificity (false-negative rate) of the test at all possible thresholds. The curve developed by such a plot is a graphic representation of the trade-off between sensitivity and specificity of the test, and the AUC is a measure of the power of the test to discriminate between the presence and absence of the condition being studied. The relative discriminatory power of two tests can be determined by comparing the AUC using established statistical techniques (23). We felt that this analytic approach was indicated because although significance levels (p values) for differences in mean values indicate how likely such observed differences would be expected to occur by chance, they do not quantify discriminatory capacity.

Using ROC analysis, we have documented that the diagnostic power of FENO for asthma is robust. The AUC observed with all flow rates and both techniques studied varied over a narrow range from 0.78 to 0.84; these values are comparable to that for serum creatine kinase MB fraction measured at 6 hours after the onset of chest pain to predict myocardial infarction (AUC = 0.778) (27). Within our study population (prevalence of asthma = 0.55), this discriminatory capacity produced a positive and negative predictive value for asthma of approximately 70% (Table 3). It is important to note that extrapolation of our findings to the general population (prevalence of asthma = 0.05) indicates that FENO as a test for asthma would demonstrate a positive predictive value of approximately 12% with a negative predictive value of 97 to 98% (Table 3). These observations suggest that FENO is most likely to be useful as an exclusionary test for asthma.

Other investigators have interpreted the currently available data regarding flow dependence of NO recordings to imply that measurements made at low flow rates "amplify the NO signal and provide better discrimination between health and disease states" (14). However, the effect of flow rate on discrimination has not been rigorously investigated. Our results, which demonstrate highly significant elevation in FENO in subjects with asthma as compared with normal subjects at each flow rate, indicate that despite flow dependence, the distinction between subjects with asthma and healthy individuals is intact at all flow rates studied. These findings are consistent with those recently published by Delclaux and colleagues that demonstrate grossly similar discrimination between individuals with asthma and healthy individuals using online NO collections at 50 ml/second as compared with those collected at 200 ml/second (28). Furthermore, we did not detect differences between either the AUC obtained using different flow rates and the same collection method (online or offline) or that obtained at similar flow rates in comparison to the alternate collection method. Thus, our analysis indicates that although the numerical differences in FENO between individuals with asthma and healthy individuals may be smaller at higher flow rates, the discriminatory power is preserved regardless of which flow or measurement technique is used. This may be due to the close correlation between online and offline techniques as well as to the decrease in the variability around the mean values observed with increased flows coupled with the sensitivity of current analyzers of approximately 0.5–1.0 parts per billion (13). Alternatively, it is possible that a difference in diagnostic power does exist and was not detected in this study. Although it is possible that a ß-type error may have occurred, we think this possibility is unlikely given the largely overlapping standard errors for the AUCs (Table 2).

Our data additionally demonstrate that recorded FENO values are inversely related to expiratory flow rate for measurements made using both online and offline techniques. These data extend and confirm those previously reported by others. Specifically, Silkoff and colleagues studied subjects without asthma and found that using online techniques, FENO increased 35-fold as expiratory flow decreased from 1,550 to 4.2 ml/second (12). We studied both individuals with asthma and healthy individuals with offline methods over the narrower range of flow rates described in recent guidelines for FENO measurement, and we documented a 3.5- to 4.5-fold increase in FENO as flow rates decreased from 500 to 50 ml/second (22). Although this increment in FENO with lower flow rates is less than that reported by Silkoff and associates, our finding is not unexpected; the largest increases in FENO in their study occurred at very low flow rates not currently used for routine NO collection and not included in our report (i.e., < 50 ml/second). Inspection of their published online data indicates that a 3- to 4-fold increase in FENO occurred over the flow range of 500–50 ml/second, similar to our findings using offline techniques.

Our findings also extend those of Kissoon and colleagues, who compared online and offline collections in healthy adolescents made at very low flow rates (4–46 ml/second) (14). We document offline flow dependence over the range of flows suggested in current ATS guidelines as well as demonstrate that the effect occurs in individuals with and without asthma regardless of the measurement technique used. This observation is important because measurement of FENO is currently being commercially marketed as a method for clinically monitoring patients with asthma, and no studies to date have systematically examined the interaction of flow dependence and measurement technique in this population.

In summary, we have documented in a systematic manner that measurement of expired NO is a robust discriminator between healthy subjects and subjects with asthma and that this discriminatory capacity is not dependent on flow rate or on which of the ATS-specified measurement methods (online or offline) are used. Furthermore, we have demonstrated that the dependence of measured FENO on expiratory flow rates occurs across the range of flows specified in current guidelines, that this dependence occurs in healthy individuals and individuals with asthma and is not restricted to measurements made with online techniques. In light of these findings, investigators and clinicians, while rigorously controlling flow during the collection maneuver and other factors outlined in the ATS guidelines (i.e., smoking status, recent upper respiratory infections), may choose a flow rate (within the range reported here) that is most comfortable and convenient for the population being studied (22). Because FENO is very sensitive to changes in expiratory flow rate, once selected, the same flow rate must be used for repeated measurements within the same individual and for legitimate comparisons between individuals. If FENO determinations are to be used in screening for asthma or monitoring of patients undergoing treatment, our results suggest that offline measurements, which provide maximally efficient use of the analyzer, can be employed without a decrement in discriminatory power.


    Acknowledgments
 
Supported by the National Institutes of Health (P50-HL-56383) and an educational grant from Merck USHH.

Received in original form January 30, 2002; accepted in final form March 19, 2002


    REFERENCES
 TOP
 ABSTRACT
 INTRODUCTION
 METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 

  1. Massaro AF, Gaston B, Kita D, Fanta C, Stamler JS, Drazen JM. Expired nitric oxide levels during treatment of acute asthma. Am J Respir Crit Care Med 1995;152:800–803.[Abstract]
  2. Yates DH, Kharitonov SA, Robbins RA, Thomas PS, Barnes PJ. Effect of a nitric oxide synthase inhibitor and a glucocorticosteroid on exhaled nitric oxide. Am J Respir Crit Care Med 1995;152:892–896.[Abstract]
  3. Kharitonov SA, Yates DH, Barnes PJ. Inhaled glucocorticoids decrease nitric oxide in exhaled air of asthmatic patients. Am J Respir Crit Care Med 1996;153:454–457.[Abstract]
  4. Bisgaard H, Loland L, Anhoj J. NO in exhaled air of asthmatic children is reduced by the leukotriene receptor antagonist montelukast. Am J Respir Crit Care Med 1999;160:1227–1231.[Abstract/Free Full Text]
  5. Tobin MJ. Asthma, airway biology, and allergic rhinitis in AJRCCM 2000. Am J Respir Crit Care Med 2001;164:1559–1580.[Free Full Text]
  6. Barnes PJ, Liew FY. Nitric oxide and asthmatic inflammation. Immunol Today 1995;16:128–130.[CrossRef][Medline]
  7. Crater SE, Peters EJ, Martin ML, Murphy AW, Platts-Mills TA. Expired nitric oxide and airway obstruction in asthma patients with an acute exacerbation. Am J Respir Crit Care Med 1999;159:806–811.[Abstract/Free Full Text]
  8. Jones SL, Kittelson J, Cowan JO, Flannery EM, Hancox RJ, McLachlan CR, Taylor DR. The predictive value of exhaled nitric oxide measurements in assessing changes in asthma control. Am J Respir Crit Care Med 2001;164:738–743.[Abstract/Free Full Text]
  9. Chatkin JM, Ansarin K, Silkoff PE, McClean P, Gutierrez C, Zamel N, Chapman KR. Exhaled nitric oxide as a noninvasive assessment of chronic cough. Am J Respir Crit Care Med 1999;159:1810–1813.[Abstract/Free Full Text]
  10. Massaro AF, Coulston E, Deykin A, Yim E, Langenauer S, Israel E, Drazen JM. Diurnal variation in expired nitric oxide in normals [abstract]. Am J Respir Crit Care Med 1998;157:a614.
  11. Georges G, Bartelson BB, Martin RJ, Silkoff PE. Circadian variation in exhaled nitric oxide in nocturnal asthma. J Asthma 1999;36:467–473.[Medline]
  12. Silkoff PE, McClean PA, Slutsky AS, Furlott HG, Hoffstein E, Wakita S, Chapman KR, Szalai JP, Zamel N. Marked flow-dependence of exhaled nitric oxide using a new technique to exclude nasal nitric oxide. Am J Respir Crit Care Med 1997;155:260–267.[Abstract]
  13. Silkoff PE, Stevens A, Pak J, Bucher-Bartelson B, Martin RJ. A method for the standardized offline collection of exhaled nitric oxide. Chest 1999;116:754–759.[Abstract/Free Full Text]
  14. Kissoon N, Duckworth LJ, Blake KV, Murphy SP, Taylor CL, Silkoff PE. FE(NO): relationship to exhalation rates and online versus bag collection in healthy adolescents. Am J Respir Crit Care Med 2000;162:539–545.[Abstract/Free Full Text]
  15. Kharitonov S, Alving K, Barnes PJ. Exhaled and nasal nitric oxide measurements: recommendations: the European Respiratory Society Task Force. Eur Respir J 1997;10:1683–1693.[CrossRef][Medline]
  16. Canady RG, Platts-Mills T, Murphy A, Johannesen R, Gaston B. Vital capacity reservoir and online measurement of childhood nitrosopnea are linearly related: clinical implications. Am J Respir Crit Care Med 1999;159:311–314.[Abstract/Free Full Text]
  17. Standards for the diagnosis and care of patients with chronic obstructive pulmonary disease (COPD) and asthma. Am Rev Respir Dis 1987;136: 225–244.[Medline]
  18. Deykin A, Halpern O, Massaro AF, Drazen JM, Israel E. Expired nitric oxide after bronchoprovocation and repeated spirometry in patients with asthma. Am J Respir Crit Care Med 1998;157:769–775.[Abstract/Free Full Text]
  19. Deykin A, Massaro AF, Coulston E, Drazen JM, Israel E. Exhaled nitric oxide following repeated spirometry or repeated plethysmography in healthy individuals. Am J Respir Crit Care Med 2000;161:1237–1240.[Abstract/Free Full Text]
  20. Silkoff PE, Wakita S, Chatkin J, Ansarin K, Gutierrez C, Caramori M, McClean P, Slutsky AS, Zamel N, Chapman KR. Exhaled nitric oxide after beta2-agonist inhalation and spirometry in asthma. Am J Respir Crit Care Med 1999;159:940–944.[Abstract/Free Full Text]
  21. Deykin A, Belostotsky O, Hong C, Massaro AF, Lilly CM, Israel E. Exhaled nitric oxide following leukotriene E4 and methacholine inhalation in patients with asthma. Am J Respir Crit Care Med 2000;162:1685–1689.[Abstract/Free Full Text]
  22. American Thoracic Society. Recommendations for the standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide in adults and children. Am J Respir Crit Care Med 1999;160:2104–2117.[Free Full Text]
  23. Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983;148:839–843.[Abstract]
  24. Massaro AF, Mehta S, Lilly CM, Kobzik L, Reilly JJ, Drazen JM. Elevated nitric oxide concentrations in isolated lower airway gas of asthmatic subjects. Am J Respir Crit Care Med 1996;153:1510–1514.[Abstract]
  25. Salome CM, Roberts AM, Brown NJ, Dermand J, Marks GB, Woolcock AJ. Exhaled nitric oxide measurements in a population sample of young adults. Am J Respir Crit Care Med 1999;159:911–916.[Abstract/Free Full Text]
  26. Silkoff PE, Sylvester JT, Zamel N, Permutt S. Airway nitric oxide diffusion in asthma: role in pulmonary function and bronchial responsiveness. Am J Respir Crit Care Med 2000;161:1218–1228.[Abstract/Free Full Text]
  27. Puleo PR, Meyer D, Wathen C, Tawa CB, Wheeler S, Hamburg RJ, Ali N, Obermueller SD, Triana JF, Zimmerman JL. Use of a rapid assay of subforms of creatine kinase-MB to diagnose or rule out acute myocardial infarction. N Engl J Med 1994;331:561–566.[Abstract/Free Full Text]
  28. Delclaux C, Mahut B, Zerah-Lancner F, Delacourt C, Laoud S, Cherqui D, Duvoux C, Mallat A, Harf A. Increased nitric oxide output from alveolar origin during liver cirrhosis versus bronchial source during asthma. Am J Respir Crit Care Med 2002;165:332–337.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
ChestHome page
K. G. Lim and C. Mottram
The Use of Fraction of Exhaled Nitric Oxide in Pulmonary Practice
Chest, May 1, 2008; 133(5): 1232 - 1242.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. Kostikas, A. I. Papaioannou, K. Tanou, A. Koutsokera, M. Papala, and K. I. Gourgoulianis
Portable Exhaled Nitric Oxide as a Screening Tool for Asthma in Young Adults During Pollen Season
Chest, April 1, 2008; 133(4): 906 - 913.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
B. Balbi, P. Pignatti, M. Corradi, P. Baiardi, L. Bianchi, G. Brunetti, A. Radaeli, G. Moscato, A. Mutti, A. Spanevello, et al.
Bronchoalveolar lavage, sputum and exhaled clinically relevant inflammatory markers: values in healthy adults
Eur. Respir. J., October 1, 2007; 30(4): 769 - 781.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C. B. Bucca, L. Brussino, A. Battisti, R. Mutani, G. Rolla, L. Mangiardi, and A. Cicolin
Diuretics in Obstructive Sleep Apnea With Diastolic Heart Failure
Chest, August 1, 2007; 132(2): 440 - 446.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
S. R Downie, C. M Salome, S. Verbanck, B. Thompson, N. Berend, and G. G King
Ventilation heterogeneity is a major determinant of airway hyperresponsiveness in asthma, independent of airway inflammation
Thorax, August 1, 2007; 62(8): 684 - 689.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
D R Taylor, M W Pijnenburg, A D Smith, and J C D Jongste
Exhaled nitric oxide measurements: clinical application and interpretation.
Thorax, September 1, 2006; 61(9): 817 - 827.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. F. Gelb, C. Flynn Taylor, C. M. Shinar, C. Gutierrez, and N. Zamel
Role of Spirometry and Exhaled Nitric Oxide To Predict Exacerbations in Treated Asthmatics
Chest, June 1, 2006; 129(6): 1492 - 1499.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
ATS Workshop Proceedings: Exhaled Nitric Oxide and Nitric Oxide Oxidative Metabolism in Exhaled Breath Condensate.
Proceedings of the ATS, January 1, 2006; 3(2): 131 - 145.
[Full Text] [PDF]


Home page
Eur Respir JHome page
P. E. Silkoff
Monitoring nitric oxide: here to stay for bench and bedside
Eur. Respir. J., June 1, 2005; 25(6): 949 - 950.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005
Am. J. Respir. Crit. Care Med., April 15, 2005; 171(8): 912 - 930.
[Full Text] [PDF]


Home page
ThoraxHome page
A Deykin and L P Malmberg
FENO as a diagnostic tool in paediatric asthma * Author's reply
Thorax, March 1, 2004; 59(3): 271 - 271.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. D. Smith, J. O. Cowan, S. Filsell, C. McLachlan, G. Monti-Sheehan, P. Jackson, and D. R. Taylor
Diagnosing Asthma: Comparisons between Exhaled Nitric Oxide Measurements and Conventional Tests
Am. J. Respir. Crit. Care Med., February 15, 2004; 169(4): 473 - 478.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
P J Franklin, S W Turner, P N Le Souef, and S M Stick
Exhaled nitric oxide and asthma: complex interactions between atopy, airway responsiveness, and symptoms in a community population of children
Thorax, December 1, 2003; 58(12): 1048 - 1052.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
P. Silkoff and A. Deykin
Exhaled nitric oxide as a diagnostic tool
Am. J. Respir. Crit. Care Med., February 15, 2003; 167(4): 665 - 666.
[Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. Tobin
Asthma, Airway Biology, and Nasal Disorders in AJRCCM 2002
Am. J. Respir. Crit. Care Med., February 1, 2003; 167(3): 319 - 332.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. P. Bowler and J. D. Crapo
Oxidative Stress in Airways: Is There a Role for Extracellular Superoxide Dismutase?
Am. J. Respir. Crit. Care Med., December 15, 2002; 166(12): S38 - 43.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Deykin, A.
Right arrow Articles by Israel, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Deykin, A.
Right arrow Articles by Israel, E.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 2002 American Thoracic Society