Finally Evidence You Can Sink Your Teeth Into |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |
ARTICLE |
|---|
|
|
|---|
In the last decade there has been an explosion of interest in using oral appliances to treat obstructive sleep apnea (OSA). Based upon available evidence they generally have been recommended for the treatment of mild OSA or simple snoring (1, 2). Oral appliances are appealing because they are simple to use, reversible, portable, and appear to be quite safe (although long-term safety data are lacking). Anterior mandibular positioners are the most commonly used appliances and the best studied.
In 1997 a much debated paper was published in the British Medical Journal that reviewed the research evidence for the health consequences of OSA and the effectiveness of continuous positive airway pressure (CPAP) therapy (3). The authors concluded that the health effects of OSA were exaggerated and that the effectiveness of CPAP in improving health outcomes had been poorly evaluated. The state of the literature on oral appliance therapy was even more deficient with few controlled trials. Many clinicians and scientists did not agree with the overall conclusions of the article (4) but most agreed that further research was needed (5). The state of the CPAP literature has improved considerably since 1997 but the debate continues (6, 7).
The majority of published trials of oral appliance therapy are small, short term, and usually retrospective in design, without any control or comparison group. Many studies have poorly defined outcome criteria, usually subjective, and have a failure of all patients to have polysomnography at baseline and outcome. Most studies exclude patients with severe OSA and include patients who failed other treatment modalities, which introduces a significant source of bias. Many studies provide little detail of the actual appliance used, the method to select the optimal amount of mandibular protrusion, or even the timing of the outcome study. The nature and severity of side effects and complications are generally not reported. To date, important outcomes of therapy such as the impact on sleepiness and performance have not been systematically evaluated and predictors of treatment success are not known. Finally, no studies have reported objective compliance and only a few have reported subjective compliance.
An article in this issue of the Journal (pp. 1457-1461) is a major step forward in correcting many of the deficiencies of the published literature (8). Mehta and colleagues have conducted the first prospective randomized placebo-controlled crossover trial of an anterior mandibular positioner for the treatment of patients with symptomatic OSA. Previous crossover studies of oral appliances have compared them with CPAP (either in a randomized [9, 10] or nonrandomized [11] design) or to another oral appliance (12). The primary aim of this randomized study was to assess efficacy of an adjustable mandibular advancement splint (MAS) and secondarily to examine whether any anthropomorphic, polysomnographic, or radiologic characteristics could predict treatment outcome.
Twenty-eight patients received an adjustable oral appliance with full occlusal coverage. The placebo was the lower
plate of the device that did not specifically alter mandibular
position. All patients had an acclimatization period during
which the mandible was incrementally advanced until symptoms resolved or maximum tolerated protrusion was obtained.
Patients were then randomly assigned to treatment with the
placebo followed by the MAS or treatment with the MAS followed by the placebo. The authors used a conservative definition of treatment success. They defined a complete response
to be a reduction in apnea/hypopnea index (AHI) to < 5/h. A
partial response was defined as an improvement in symptoms
combined with a
50% reduction in AHI but the AHI remained > 5/h. Treatment failures were defined as having ongoing symptoms and/or a < 50% reduction in AHI. Compliance failure was defined as an inability of the patient to use
the treatment. Other outcomes included the effects on sleep
structure, oxygenation, and snoring and questionnaires evaluating snoring, quality of sleep, and daytime sleepiness.
The patients were typical of a population of OSA patients
middle aged, overweight, and mostly male. One important strength of this study is that it included patients who
had a range of severity of OSA with AHI between 10 and 68/h.
The placebo device had no impact on the AHI or on oxygen
saturation. The MAS resulted in a partial or complete response in 15 patients or 62.5% (complete response in 9
37.5%). Other studies have used a cutoff of an AHI of 10/h to
define treatment success and 71% of patients had a complete
or partial response by this criteria. The MAS had beneficial effects on the amount of rapid eye movement (REM) sleep,
snoring intensity and frequency, the number of arousals, and
oxygenation. Patients tolerated the treatment well and reported improvements in sleep quality and daytime sleepiness.
Side effects were few and there were no complications. They
found four independent predictors of the treated AHI
neck
circumference, baseline AHI, and two cephalometric variables. The predictive equation requires validation to see if it is
generalizable to other patient populations.
This study provides confirmation of the efficacy of adjustable mandibular positioner therapy in some patients with
OSA. They had good results in patients with more significant
OSA (AHI
40) and many patients elected to continue on
with MAS therapy as they had a good symptomatic response.
Subjective response to the MAS was clearly superior to the
objective response (reduction in AHI). The study suggests
that the mechanism of action of oral appliances is mandibular
advancement because the presence of an intraoral device
without advancement showed no clinical benefit.
Long-term studies are still required that objectively evaluate performance and sleepiness and that monitor for complications that may not emerge for several years. Perhaps these authors will continue to follow these patients and report later on their long-term outcome. On the horizon for the field of oral appliance therapy is the introduction of a compliance monitor that will allow an objective determination of appliance usage. In addition, several investigators are developing systems that would allow overnight titration of oral appliances in the sleep laboratory. Results from this study support the use of this treatment in patients with symptomatic OSA as long as a follow-up sleep evaluation occurs.
| |
References |
|---|
|
|
|---|
1. Schmidt-Nowara W, Lowe A, Wiegand L, Cartwright R, Perez-Guerra F, Menn S. Oral appliances for the treatment of snoring and obstructive sleep apnea: a review. Sleep 1995; 18: 501-510 [Medline].
2. American Sleep Disorders Association. Practice parameters for the treatment of snoring and obstructive sleep apnea with oral appliances. Sleep 1995;18:511-513.
3.
Wright J,
Johns R,
Watt I,
Melville A,
Sheldon T.
Health effects of obstructive sleep apnoea and the effectiveness of continuous positive airways pressure: a systematic review of the research evidence [see comments].
BMJ
1997;
314:
851-860
4. Stradling J. Sleep apnoea and the misuse of evidence-based medicine. Lancet 1997; 349: 201-202 [Medline].
5.
Fleetham JA.
A wake up call for sleep disordered breathing.
BMJ
1997;
314:
839-840
6.
Davies RJ,
Stradling JR.
The efficacy of nasal continuous positive airway pressure in the treatment of obstructive sleep apnea syndrome is
proven.
Am J Respir Crit Care Med
2000;
161:
1775-1776
7.
Wright J,
Sheldon T.
The efficacy of nasal continuous positive airway
pressure in the treatment of obstructive sleep apnea syndrome is not
proven.
Am J Respir Crit Care Med
2000;
161:
1776-1778
8.
Mehta A,
Qian J,
Petocz P,
Darendeliler MA,
Cistulli PA.
A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea.
Am J Respir Crit Care Med
2001;
163:
1457-1461
9.
Ferguson KA,
Ono T,
Lowe AA,
Keenan SP,
Fleetham JA.
A randomized crossover study of an oral appliance vs nasal-continuous positive
airway pressure in the treatment of mild-moderate obstructive sleep
apnea.
Chest
1996;
109:
1269-1275
10. Ferguson KA, Ono T, Lowe AA, Al-Majed S, Love LL, Fleetham JA. A short term controlled trial of an adjustable oral appliance for the treatment of mild to moderate obstructive sleep apnoea. Thorax 1997; 52: 362-368 [Abstract].
11.
Clark GT,
Blumenfeld I,
Yoffe N,
Peled E,
Lavie P.
A crossover study
comparing the efficacy of continuous positive airway pressure with anterior mandibular positioning devices on patients with obstructive
sleep apnea.
Chest
1996;
109:
1477-1483
12.
Bloch KE,
Iseli A,
Zhang JN,
Xie X,
Kaplan V,
Stoeckli PW,
Russi EW.
A randomized, controlled crossover trial of two oral appliances for
sleep apnea treatment.
Am J Respir Crit Care Med
2000;
162:
246-251
This article has been cited by other articles:
![]() |
K. Kairaitis, R. Stavrinou, R. Parikh, J. R. Wheatley, and T. C. Amis Mandibular advancement decreases pressures in the tissues surrounding the upper airway in rabbits J Appl Physiol, January 1, 2006; 100(1): 349 - 356. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. I. Pack Should a Pharmaceutical Be Approved for the Broad Indication of Excessive Sleepiness? Am. J. Respir. Crit. Care Med., January 15, 2003; 167(2): 109 - 111. [Full Text] [PDF] |
||||
![]() |
A. J. Pitsis, M. A. Darendeliler, H. Gotsopoulos, P. Petocz, and P. A. Cistulli Effect of Vertical Dimension on Efficacy of Oral Appliance Therapy in Obstructive Sleep Apnea Am. J. Respir. Crit. Care Med., September 15, 2002; 166(6): 860 - 864. [Abstract] [Full Text] |
||||
![]() |
H. Gotsopoulos, C. Chen, J. Qian, and P. A. Cistulli Oral Appliance Therapy Improves Symptoms in Obstructive Sleep Apnea: A Randomized, Controlled Trial Am. J. Respir. Crit. Care Med., September 1, 2002; 166(5): 743 - 748. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. TOBIN Sleep-Disordered Breathing, Control of Breathing, Respiratory Muscles, and Pulmonary Function Testing in AJRCCM 2001 Am. J. Respir. Crit. Care Med., March 1, 2002; 165(5): 584 - 597. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Proc. Am. Thorac. Soc. | Am. J. Respir. Cell Mol. Biol. |