Published ahead of print on December 23, 2003, doi:10.1164/rccm.200301-133OC
American Journal of Respiratory and Critical Care Medicine Vol 169. pp. 791-800, (2004)
© 2004 American Thoracic Society
Imbalances in Regional Lung Ventilation
A Validation Study on Electrical Impedance Tomography
Josué A. Victorino,
João B. Borges,
Valdelis N. Okamoto,
Gustavo F. J. Matos,
Mauro R. Tucci,
Maria P. R. Caramez,
Harki Tanaka,
Fernando Suarez Sipmann,
Durval C. B. Santos,
Carmen S. V. Barbas,
Carlos R. R. Carvalho and
Marcelo B. P. Amato
Respiratory ICU, Hospital das Clínicas, Pulmonary Department; General ICU, Hospital das Clínicas, Emergency Clinics Division; Radiology Department, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil; and Department of Intensive Care, Fundación Jiménez Díaz, Madrid, Spain
Correspondence and requests for reprints should be addressed to Marcelo Amato, M.D., Laboratório de Pneumologia, LIM09, Faculdade de Medicina da USP, Av Dr Arnaldo, 455 sala 2206 (2nd floor), CEP: 01246903, São Paulo, SP, Brazil. E-mail: amato{at}unisys.com.br
Imbalances in regional lung ventilation, with gravity-dependent collapse and overdistention of nondependent zones, are likely associated to ventilator-induced lung injury. Electric impedance tomography is a new imaging technique that is potentially capable of monitoring those imbalances. The aim of this study was to validate electrical impedance tomography measurements of ventilation distribution, by comparison with dynamic computerized tomography in a heterogeneous population of critically ill patients under mechanical ventilation. Multiple scans with both devices were collected during slow-inflation breaths. Six repeated breaths were monitored by impedance tomography, showing acceptable reproducibility. We observed acceptable agreement between both technologies in detecting rightleft ventilation imbalances (bias = 0% and limits of agreement = -10 to +10%). Relative distribution of ventilation into regions or layers representing one-fourth of the thoracic section could also be assessed with good precision. Depending on electrode positioning, impedance tomography slightly overestimated ventilation imbalances along gravitational axis. Ventilation was gravitationally dependent in all patients, with some transient blockages in dependent regions synchronously detected by both scanning techniques. Among variables derived from computerized tomography, changes in absolute air content best explained the integral of impedance changes inside regions of interest (r2 0.92). Impedance tomography can reliably assess ventilation distribution during mechanical ventilation.
Key Words: artificial respiration physiologic monitoring validation studies adult respiratory distress syndrome respiratory insufficiency
This article has been cited by other articles:

|
 |

|
 |
 
D. Steinmann, C. A. Stahl, J. Minner, S. Schumann, T. Loop, A. Kirschbaum, H. J. Priebe, and J. Guttmann
Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study
Br. J. Anaesth.,
September 1, 2008;
101(3):
411 - 418.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. K. Fuld, R. B. Easley, O. I. Saba, D. Chon, J. M. Reinhardt, E. A. Hoffman, and B. A. Simon
CT-measured regional specific volume change reflects regional ventilation in supine sheep
J Appl Physiol,
April 1, 2008;
104(4):
1177 - 1184.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. S. Syring, C. M. Otto, R. E. Spivack, K. Markstaller, and J. E. Baumgardner
Maintenance of end-expiratory recruitment with increased respiratory rate after saline-lavage lung injury
J Appl Physiol,
January 1, 2007;
102(1):
331 - 339.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
I. Frerichs, P. A. Dargaville, H. van Genderingen, D. R. Morel, and P. C. Rimensberger
Lung Volume Recruitment after Surfactant Administration Modifies Spatial Distribution of Ventilation
Am. J. Respir. Crit. Care Med.,
October 1, 2006;
174(7):
772 - 779.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. D. Macnaughton
New ventilators for the ICU--usefulness of lung performance reporting
Br. J. Anaesth.,
July 1, 2006;
97(1):
57 - 63.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. Pfeiffer, R. S. Syring, K. Markstaller, C. M. Otto, and J. E. Baumgardner
The implications of arterial po2 oscillations for conventional arterial blood gas analysis.
Anesth. Analg.,
June 1, 2006;
102(6):
1758 - 1764.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. Michelet, A. Roch, D. Brousse, X.-B. D'Journo, F. Bregeon, D. Lambert, G. Perrin, L. Papazian, P. Thomas, J.-P. Carpentier, et al.
Effects of PEEP on oxygenation and respiratory mechanics during one-lung ventilation
Br. J. Anaesth.,
August 1, 2005;
95(2):
267 - 273.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Angus, A. Ishizaka, M. Matthay, F. Lemaire, W. MacNee, and E. Abraham
Critical Care in AJRCCM 2004
Am. J. Respir. Crit. Care Med.,
March 15, 2005;
171(6):
537 - 544.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Hedenstierna
Using Electric Impedance Tomography to Assess Regional Ventilation at the Bedside
Am. J. Respir. Crit. Care Med.,
April 1, 2004;
169(7):
777 - 778.
[Full Text]
[PDF]
|
 |
|
Copyright © 2004 American Thoracic Society
|
|
|