help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MAURY, E.
Right arrow Articles by OFFENSTADT, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MAURY, E.
Right arrow Articles by OFFENSTADT, G.

Am. J. Respir. Crit. Care Med., Volume 164, Number 3, August 2001, 403-405

Ultrasonic Examination
An Alternative to Chest Radiography after Central Venous Catheter Insertion?

ERIC MAURY, JEAN GUGLIELMINOTTI, MARC ALZIEU, BERTRAND GUIDET, and GEORGES OFFENSTADT

Service de Réanimation Médicale, Hôpital Saint-Antoine, Assistance Publique-Hôpitaux de Paris, Paris, France

We evaluated ultrasonic examination as a diagnostic tool for catheter misplacement and pneumothorax after central venous catheter insertion. Physicians in the intensive care unit (ICU) performed the ultrasonic examinations, and the results were compared with those of chest radiography. Eighty-five central venous catheters (70 subclavian and 15 internal jugular) were inserted into 81 patients; 10 misplacements and one pneumothorax occurred. Ultrasonic examination feasibility was 99.6%. The only pneumothorax and all misplacements except one were diagnosed by ultrasound. Taking into consideration misplacements and pneumothorax research, ultrasonic examination did not give any false positive results. The mean time of the entire ultrasonic examination was 6.8 ± 3.5 min, whereas 80.3 ± 66.7 min were needed for the radiography (p < 0.0001). This study has suggested that ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is a rapid and accurate method that can be easily performed by ICU physicians.

Keywords: central venous catheter; complications; malposition; pneumothorax; ultrasound




This article has been cited by other articles:


Home page
ChestHome page
D. Feller-Kopman
Ultrasound-Guided Internal Jugular Access: A Proposed Standardized Approach and Implications for Training and Practice
Chest, July 1, 2007; 132(1): 302 - 309.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. Feller-Kopman
Ultrasound-Guided Thoracentesis
Chest, June 1, 2006; 129(6): 1709 - 1714.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Slater, M. Goodwin, K. E. Anderson, and F. V. Gleeson
COPD Can Mimic the Appearance of Pneumothorax on Thoracic Ultrasound
Chest, March 1, 2006; 129(3): 545 - 550.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. TOBIN
Critical Care Medicine in AJRCCM 2001
Am. J. Respir. Crit. Care Med., March 1, 2002; 165(5): 565 - 583.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 2001 American Thoracic Society