help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by CANNON, M. L.
Right arrow Articles by CHEIFETZ, I. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by CANNON, M. L.
Right arrow Articles by CHEIFETZ, I. M.

Am. J. Respir. Crit. Care Med., Volume 162, Number 6, December 2000, 2109-2112

Tidal Volumes For Ventilated Infants Should Be Determined with a Pneumotachometer Placed at the Endotracheal Tube

MICHAEL L. CANNON, JACK CORNELL, DONNA S. TRIPP-HAMEL, MICHAEL A. GENTILE, CHRISTOPHER L. HUBBLE, JON N. MELIONES, and IRA M. CHEIFETZ

Divisions of Pediatric Critical Care Medicine and Pediatric Respiratory Care, Duke Children's Hospital, Duke University Medical Center, Durham, North Carolina

Many ventilators measure expired tidal volume (VT) without compensation either for the compliance of the ventilator circuit or for variations in the circuit setup. We hypothesized that the exhaled VT measured with a conventional ventilator at the expiratory valve would differ significantly from the exhaled VT measured with a pneumotachometer placed at the endotracheal tube. To investigate this we studied 98 infants and children requiring conventional ventilation. We used linear regression analysis to compare the VT obtained with the pneumotachometer with the ventilator-measured volume. An additional comparison was made between the pneumotachometer volume and a calculated effective VT. For infant circuits (n = 70), our analysis revealed a poor correlation between the expiratory VT measured with the pneumotachometer and the ventilator-measured volume (r2 = 0.54). Similarly, the expiratory VT measured with the pneumotachometer did not correlate with the calculated effective volume (r2 = 0.58). For pediatric circuits (n = 28), there was improved correlation between the expiratory VT measured with the pneumotachometer and both the ventilator-measured volume and the calculated effective VT (r2 = 0.84 and r2 = 0.85, respectively). The data demonstrate a significant discrepancy between expiratory VT measured at a ventilator and that measured with a pneumotachometer placed at the endotracheal tube in infants. Correcting for the compliance of the ventilator circuit by calculating the effective VT did not alter this discrepancy. In conventionally ventilated infants, exhaled VT should be determined with a pneumotachometer placed at the airway.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
P. R. Bachiller, J. M. McDonough, and J. M. Feldman
Do New Anesthesia Ventilators Deliver Small Tidal Volumes Accurately During Volume-Controlled Ventilation?
Anesth. Analg., May 1, 2008; 106(5): 1392 - 1400.
[Abstract] [Full Text] [PDF]


Home page
NeoReviewsHome page
M. Keszler
Volume-targeted Ventilation
NeoReviews, May 1, 2006; 7(5): e250 - e257.
[Full Text] [PDF]


Home page
Eur Respir JHome page
R. Farre, S. J. Lloyd-Owen, N. Ambrosino, G. Donaldson, J. Escarrabill, B. Fauroux, D. Robert, B. Schoenhofer, A. Simonds, and J. A. Wedzicha
Quality control of equipment in home mechanical ventilation: a European survey
Eur. Respir. J., July 1, 2005; 26(1): 86 - 94.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. G. Randolph, K. L. Meert, M. E. O'Neil, J. H. Hanson, P. M. Luckett, J. H. Arnold, R. G. Gedeit, P. N. Cox, J. S. Roberts, S. T. Venkataraman, et al.
The Feasibility of Conducting Clinical Trials in Infants and Children with Acute Respiratory Failure
Am. J. Respir. Crit. Care Med., May 15, 2003; 167(10): 1334 - 1340.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
S. E. Courtney, D. J. Durand, J. M. Asselin, M. L. Hudak, J. L. Aschner, C. T. Shoemaker, and the Neonatal Ventilation Study Group
High-Frequency Oscillatory Ventilation versus Conventional Mechanical Ventilation for Very-Low-Birth-Weight Infants
N. Engl. J. Med., August 29, 2002; 347(9): 643 - 652.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. TOBIN
Pediatrics, Surfactant, and Cystic Fibrosis in AJRCCM 2000
Am. J. Respir. Crit. Care Med., November 1, 2001; 164(9): 1581 - 1594.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 2000 American Thoracic Society
  ATS Quiz on Sleep Study Tracings