help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by JONES, M. H.
Right arrow Articles by TEPPER, R. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by JONES, M. H.
Right arrow Articles by TEPPER, R. S.

Am. J. Respir. Crit. Care Med., Volume 161, Number 3, March 2000, 713-717

Flow Limitation in Infants Assessed by Negative Expiratory Pressure

MARCUS H. JONES, STEPHANIE D. DAVIS, JEFFREY A. KISLING, JOHN M. HOWARD, ROBERT CASTILE, and ROBERT S. TEPPER

Riley Children's Hospital, Indianapolis, Indiana; and Columbus Children's Hospital, Columbus, Ohio

Forced expiratory flows by the rapid compression technique are often used to assess airway function in infants; however, it remains unclear as to whether flow limitation (FL) is achieved. Studies in adults have used negative expiratory pressure (NEP) at the airway opening as a noninvasive technique to assess whether FL is achieved. An increase in flow with NEP indicates that FL has not been achieved, whereas no increase in flow with NEP indicates FL has been achieved. In the adult studies, the change in flow was assessed by visual inspection of the flow-volume curve. We evaluated whether NEP could be used to assess FL during forced expiration in infants. In addition, we quantified the change in flow secondary to NEP. We applied -5 cm H2O NEP to four infants during forced expiratory maneuvers. The step increase in flow with NEP was always less than 5% at high jacket compression pressures and consistent with FL. For one subject, FL was also confirmed from isovolume pressure flow-curves measured with an esophageal catheter. We conclude that NEP can be used in infants to assess FL during forced expiratory maneuvers by the rapid compression technique. Jones MH, Davis SD, Kisling JA, Howard JM, Castile R, Tepper RS. Flow limitation in infants assessed by negative expiratory pressure.




This article has been cited by other articles:


Home page
Eur Respir JHome page
P. M. A. Calverley and N. G. Koulouris
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Eur. Respir. J., January 1, 2005; 25(1): 186 - 199.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. Martinez, A. Weist, T. Williams, C. Clem, P. Silkoff, and R. S. Tepper
Assessment of exhaled nitric oxide kinetics in healthy infants
J Appl Physiol, June 1, 2003; 94(6): 2384 - 2390.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. H. Jones, J. Howard, S. Davis, J. Kisling, and R. S. Tepper
Sensitivity of Spirometric Measurements to Detect Airway Obstruction in Infants
Am. J. Respir. Crit. Care Med., May 1, 2003; 167(9): 1283 - 1286.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. TOBIN
Pediatrics, Surfactant, and Cystic Fibrosis in AJRCCM 2000
Am. J. Respir. Crit. Care Med., November 1, 2001; 164(9): 1581 - 1594.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 2000 American Thoracic Society
  ATS Par News