help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by BADIA, J. R.
Right arrow Articles by MONTSERRAT, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by BADIA, J. R.
Right arrow Articles by MONTSERRAT, J. M.

Am. J. Respir. Crit. Care Med., Volume 160, Number 5, November 1999, 1550-1554

Clinical Application of the Forced Oscillation Technique for CPAP Titration in the Sleep Apnea/Hypopnea Syndrome

JOAN R. BADIA, RAM OŃ FARRÉ, R. JOHN KIMOFF, EUGENI BALLESTER, LOURDES HERNÁNDEZ, MAR ROTGER, DANIEL NAVAJAS, and JOSEP M. MONTSERRAT

Servei de Pneumologia i Al·lèrgia Respiratòria, Departament de Medicina, Hospital Clínic, Laboratori de Biofísica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Barcelona, Spain; and Royal Victoria Hospital, Respiratory Division de Pneumologie, Montréal, Quebec, Canada

We have previously demonstrated that upper airway obstruction in sleep apnea/hypopnea syndrome (SAHS) can be accurately assessed in real-time by measuring respiratory impedance (|Z|) with the forced oscillation technique (FOT). The aims of the present study were: (1) to determine the feasibility of identifying the optimal continuous positive airway pressure (CPAP) for patients with SAHS based on analysis of the |Z| signal during conventional polysomnographic CPAP titration studies; and (2) to evaluate practical issues involved in the application of FOT during CPAP titration. We performed CPAP titration in 28 patients with SAHS during polysomnography (PSG) (14 nap and 14 full overnight studies) using a FOT system applied continuously to obtain an on-line measurement of |Z|. FOT was easily implemented and was well-tolerated by the patients. Optimal CPAP levels were determined both in the conventional manner from the standard PSG titration record and during a separate blinded analysis using the FOT signal alone. The mean conventional versus FOT-based optimal CPAP values were similar for both nap studies (10.6 ± 0.6 [mean ± SEM] versus 11.1 ± 0.6 cm H2O, respectively, p = 0.054) and overnight studies (9.9 ± 0.7 versus 9.9 ± 0.6 cm H2O, respectively, p = 1.00). Subsequent analysis of the PSG record with the FOT signal incorporated demonstrated that artefacts in the |Z| tracing occurred during mask leak, mouth breathing, and movement during arousal. Such abnormalities were readily identified from the flow tracing. These results indicate that, for adequate interpretation, the tracing and values of respiratory impedance obtained by FOT should be evaluated in conjunction with the flow signal. Continuous FOT-guided CPAP titration is feasible and may be a useful adjunct during manual titration. FOT could also potentially serve as the basis for automated CPAP in SAHS. Badia JR, Farré R, Kimoff RJ, Ballester E, Hernández L, Rotger M, Navajas D, Montserrat JM. Clinical application of the forced oscillation technique for CPAP titration in the sleep apnea/hypopnea syndrome.




This article has been cited by other articles:


Home page
ChestHome page
J. Rigau, J. M. Montserrat, H. Wohrle, D. Plattner, M. Schwaibold, D. Navajas, and R. Farre
Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
Chest, August 1, 2006; 130(2): 350 - 361.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R. Farre, J.M. Montserrat, and D. Navajas
Noninvasive monitoring of respiratory mechanics during sleep
Eur. Respir. J., December 1, 2004; 24(6): 1052 - 1060.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. A. Pevernagie, P. M. Proot, K. B. Hertegonne, M. C. Neyens, K. P. Hoornaert, and R. A. Pauwels
Efficacy of Flow- vs Impedance-Guided Autoadjustable Continuous Positive Airway Pressure: A Randomized Cross-over Trial
Chest, July 1, 2004; 126(1): 25 - 30.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
E. Oostveen, D. MacLeod, H. Lorino, R. Farre, Z. Hantos, K. Desager, and F. Marchal
The forced oscillation technique in clinical practice: methodology, recommendations and future developments
Eur. Respir. J., December 1, 2003; 22(6): 1026 - 1041.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. Kessler, E. Weitzenblum, A. Chaouat, C. Iamandi, and T. Alliotte
Evaluation of Unattended Automated Titration To Determine Therapeutic Continuous Positive Airway Pressure in Patients With Obstructive Sleep Apnea
Chest, March 1, 2003; 123(3): 704 - 710.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
H. Steltner, R. Staats, J. Timmer, M. Vogel, J. Guttmann, H. Matthys, and J. Christian Virchow
Diagnosis of Sleep Apnea by Automatic Analysis of Nasal Pressure and Forced Oscillation Impedance
Am. J. Respir. Crit. Care Med., April 1, 2002; 165(7): 940 - 944.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J. Rigau, R. Farre, J. Roca, S. Marco, A. Herms, and D. Navajas
A portable forced oscillation device for respiratory home monitoring
Eur. Respir. J., January 1, 2002; 19(1): 146 - 150.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J.R. Badia, R. Farre, J. Rigau, M.E. Uribe, D. Navajas, and J.M. Montserrat
Forced oscillation measurements do not affect upper airway muscle tone or sleep in clinical studies
Eur. Respir. J., August 1, 2001; 18(2): 335 - 339.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R. Farre, J. Rigau, J.M. Montserrat, E. Ballester, and D. Navajas
Evaluation of a simplified oscillation technique for assessing airway obstruction in sleep apnoea
Eur. Respir. J., March 1, 2001; 17(3): 456 - 461.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
W. J. RANDERATH, O. SCHRAEDER, W. GALETKE, F. FELDMEYER, and K.-H. RUHLE
Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
Am. J. Respir. Crit. Care Med., March 1, 2001; 163(3): 652 - 657.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1999 American Thoracic Society
  ATS Coding and Billing Quarterly