help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LORENZI-FILHO, G.
Right arrow Articles by BRADLEY, T. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LORENZI-FILHO, G.
Right arrow Articles by BRADLEY, T. D.

Am. J. Respir. Crit. Care Med., Volume 159, Number 4, April 1999, 1147-1154

Entrainment of Blood Pressure and Heart Rate Oscillations by Periodic Breathing

GERALDO LORENZI-FILHO, HILMI R. DAJANI, RICHARD S. T. LEUNG, JOHN S. FLORAS, and T. DOUGLAS BRADLEY

Sleep Research Laboratory, Mount Sinai Hospital; and Department of Medicine, The Toronto Hospital, University of Toronto, Toronto, Canada

Cheyne-Stokes respiration (CSR) is a form of periodic breathing associated with periodic oscillations in blood pressure (BP) and heart rate (HR), which have been attributed to hypoxia and arousals from sleep. We hypothesized that periodic alterations in ventilation alone would promote oscillations in BP and HR. Seven healthy, wakeful subjects breathed in three patterns, as follows: (1) regular breathing (RB); (2) periodic breathing with three (PB3: cycle frequency = 0.035 Hz) augmented breaths alternating with 20-s apneas; and (3) periodic breathing with five (PB5: cycle frequency = 0.030 Hz) augmented breaths alternating with 20-s apneas. SaO2 remained above 95% throughout. During periodic breathing, peaks in BP and HR occurred during the ventilatory period and troughs occurred during apnea. The magnitudes of systolic BP oscillations increased significantly from RB (14 ± 5 mm Hg) to PB3 (20 ± 4 mm Hg) and PB5 (25 ± 7 mm Hg; p < 0.005). HR oscillations also increased from regular breathing (13 ± 6.0 beats/min) to PB3 (20.2 ± 2.3 beats/min) and PB5 (20.2 ± 4.7 beats/ min; p < 0.01). Spectral analysis showed that during periodic breathing there were discrete peaks in the spectral power of ventilation, BP, and R-wave-to-R-wave interval at the periodic breathing cycle frequencies. We conclude that oscillations in ventilation occurring during periodic breathing can amplify and entrain oscillations in BP and HR in the absence of hypoxia or arousals from sleep.




This article has been cited by other articles:


Home page
Proc Am Thorac SocHome page
D. Yumino and T. D. Bradley
Central Sleep Apnea and Cheyne-Stokes Respiration
Proceedings of the ATS, February 15, 2008; 5(2): 226 - 236.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
G. Lorenzi-Filho and L. F. Drager
Obstructive Sleep Apnea and Atherosclerosis: A New Paradigm
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1219 - 1221.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
Y.-C. P. Arai, M. Nakayama, N. Kato, Y. Wakao, H. Ito, and T. Komatsu
The Effects of Jaw Thrust and the Lateral Position on Heart Rate Variability in Anesthetized Children with Obstructive Sleep Apnea Syndrome
Anesth. Analg., June 1, 2007; 104(6): 1352 - 1355.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
A. Vazir, M. Dayer, P. C. Hastings, H. F. McIntyre, M. Y. Henein, P. A. Poole-Wilson, M. R. Cowie, M. J. Morrell, and A. K. Simonds
Can heart rate variation rule out sleep-disordered breathing in heart failure?
Eur. Respir. J., March 1, 2006; 27(3): 571 - 577.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. S. T. Leung, M. E. Bowman, T. M. Diep, G. Lorenzi-Filho, J. S. Floras, and T. D. Bradley
Influence of Cheyne-Stokes respiration on ventricular response to atrial fibrillation in heart failure
J Appl Physiol, November 1, 2005; 99(5): 1689 - 1696.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J. Y. Gabor, D. A. Newman, V. Barnard-Roberts, V. Korley, I. Mangat, P. Dorian, and P. J. Hanly
Improvement in Cheyne-Stokes respiration following cardiac resynchronisation therapy
Eur. Respir. J., July 1, 2005; 26(1): 95 - 100.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
T. Brack, A. Jubran, F. Laghi, and M. J. Tobin
Fluctuations in End-Expiratory Lung Volume during Cheyne-Stokes Respiration
Am. J. Respir. Crit. Care Med., June 15, 2005; 171(12): 1408 - 1413.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
F. Yasuma and J.-i. Hayano
Respiratory Sinus Arrhythmia: Why Does the Heartbeat Synchronize With Respiratory Rhythm?
Chest, February 1, 2004; 125(2): 683 - 690.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. S. Jordan, D. J. Eckert, P. G. Catcheside, and R. D. McEvoy
Ventilatory Response to Brief Arousal from Non-Rapid Eye Movement Sleep Is Greater in Men Than in Women
Am. J. Respir. Crit. Care Med., December 15, 2003; 168(12): 1512 - 1519.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
K. Dingli, T. Assimakopoulos, P.K. Wraith, I. Fietze, C. Witt, and N.J. Douglas
Spectral oscillations of RR intervals in sleep apnoea/hypopnoea syndrome patients
Eur. Respir. J., December 1, 2003; 22(6): 943 - 950.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. J. Leite, A. J. Mansur, H. F. G. de Freitas, P. R. Chizola, E. A. Bocchi, M. Terra-Filho, J. A. Neder, and G. Lorenzi-Filho
Periodic breathing during incremental exercise predicts mortality in patients with chronic heart failure evaluated for cardiac transplantation
J. Am. Coll. Cardiol., June 18, 2003; 41(12): 2175 - 2181.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. S. T. Leung, J. S. Floras, G. Lorenzi-Filho, F. Rankin, P. Picton, and T. D. Bradley
Influence of Cheyne-Stokes Respiration on Cardiovascular Oscillations in Heart Failure
Am. J. Respir. Crit. Care Med., June 1, 2003; 167(11): 1534 - 1539.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. D. Bradley and J. S. Floras
Sleep Apnea and Heart Failure: Part II: Central Sleep Apnea
Circulation, April 8, 2003; 107(13): 1822 - 1826.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
L. Spicuzza, L. Bernardi, A. Calciati, and G. U. Di Maria
Autonomic Modulation of Heart Rate during Obstructive versus Central Apneas in Patients with Sleep-disordered Breathing
Am. J. Respir. Crit. Care Med., March 15, 2003; 167(6): 902 - 910.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Gori, J. S. Floras, and J. D. Parker
Effects of nitroglycerin treatment on baroreflex sensitivity andshort-term heart rate variability in humans
J. Am. Coll. Cardiol., December 4, 2002; 40(11): 2000 - 2005.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. S. T. LEUNG and T. DOUGLAS BRADLEY
Sleep Apnea and Cardiovascular Disease
Am. J. Respir. Crit. Care Med., December 15, 2001; 164(12): 2147 - 2165.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. Trinder, M. Padula, D. Berlowitz, J. Kleiman, S. Breen, P. Rochford, C. Worsnop, B. Thompson, and R. Pierce
Cardiac and respiratory activity at arousal from sleep under controlled ventilation conditions
J Appl Physiol, April 1, 2001; 90(4): 1455 - 1463.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. Insalaco, S. Romano, A. Salvaggio, A. Braghiroli, P. Lanfranchi, V. Patruno, O. Marrone, M. R. Bonsignore, C. F. Donner, and G. Bonsignore
Blood pressure and heart rate during periodic breathing while asleep at high altitude
J Appl Physiol, September 1, 2000; 89(3): 947 - 955.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. TRINDER, R. MERSON, J. I. ROSENBERG, F. FITZGERALD, J. KLEIMAN, and T. DOUGLAS BRADLEY
Pathophysiological Interactions of Ventilation, Arousals, and Blood Pressure Oscillations during Cheyne-Stokes Respiration in Patients with Heart Failure
Am. J. Respir. Crit. Care Med., September 1, 2000; 162(3): 808 - 813.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1999 American Thoracic Society