help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by FUJINO, Y.
Right arrow Articles by KACMAREK, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by FUJINO, Y.
Right arrow Articles by KACMAREK, R. M.

Am. J. Respir. Crit. Care Med., Volume 159, Number 4, April 1999, 1087-1095

The Effect of Mode, Inspiratory Time, and Positive End-Expiratory Pressure on Partial Liquid Ventilation

YUJI FUJINO, MAX KIRMSE, DEAN HESS, and ROBERT M. KACMAREK

Respiratory Care Department Laboratory and the Department of Anesthesia, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts

Partial liquid ventilation (PLV) has been shown to be an effective means of improving oxygenation in the injured lung. However, little is known about how approach to ventilation during PLV affects gas exchange and pulmonary mechanics. We hypothesized that gas exchange and pulmonary mechanics would be best with positive end-expiratory pressure (PEEP) set above the lower inflection point (LIP) of the pressure-volume (P-V) curve regardless of mode of ventilation or inspiratory to expiratory time (I:E) ratio and that the efficiency of ventilation would be greatest with volume-controlled ventilation (VCV) compared with pressure-controlled ventilation (PCV) and with long inspiratory time as compared with short inspiratory time. Lung injury was induced in 14 sheep by lavage, 10 of which were studied. Sheep were then assigned to high-PEEP (Group H, n = 5) and low-PEEP (Group L, n = 5) groups. In Group H applied PEEP was set at the LIP and in Group L applied PEEP was set at 5 cm H2O after the lung was filled with perflubron (PFB). We randomly compared VCV and PCV with I:E ratios of 1:2, 1:1, and 2:1. Peak inspiratory pressure and VT were adjusted to maintain a constant end-inspiratory plateau pressure (Pplat) of about 25 cm H2O in both groups and a constant total PEEP of about 5 cm H2O in Group L and about 12 cm H2O in Group H. There were no differences in oxygenation among modes in Group H. In Group L VCV 2:1 and all of the PCV modes in Group L had a lower PaO2 than VCV 1:1 (p < 0.05). PaCO2 and VD/VT were significantly different (p < 0.05) among modes. VD/VT was highest during PCV 1:2 with PEEP of 5 cm H2O (p < 0.05). Quasi-static compliance in Group H was higher than in Group L (p < 0.05). We conclude that during low PEEP gas exchange deteriorated in VCV with long inspiratory time and in PCV. Oxygenation was enhanced during VCV 1:1 when compared with VCV at longer I:E ratios or PCV at any I:E ratio. With PEEP set at the LIP, adequate gas exchange and improved lung mechanics could be obtained in all modes assessed.




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
J.-D. Ricard, D. Dreyfuss, J.-P. Laissy, and G. Saumon
Dose-Response Effect of Perfluorocarbon Administration on Lung Microvascular Permeability in Rats
Am. J. Respir. Crit. Care Med., December 1, 2003; 168(11): 1378 - 1382.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
S.A. Loer, D. Kindgen-Milles, and J. Tarnow
Partial liquid ventilation: effects of liquid volume and ventilatory settings on perfluorocarbon evaporation
Eur. Respir. J., December 1, 2002; 20(6): 1499 - 1504.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. T. Harrington, B. S. Jordan, M. A. Dubick, L. C. Cancio, W. Brinkley, S. Kim, D. G. Burleson, A. Delgado, and C. W. Goodwin
Delayed partial liquid ventilation shows no efficacy in the treatment of smoke inhalation injury in swine
J Appl Physiol, June 1, 2001; 90(6): 2351 - 2360.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
Y. FUJINO, S. GODDON, J.-D. CHICHE, J. HROMI, and R. M. KACMAREK
Partial Liquid Ventilation Ventilates Better than Gas Ventilation
Am. J. Respir. Crit. Care Med., August 1, 2000; 162(2): 650 - 657.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
G. Ferreyra, S. Goddon, Y. Fujino, and R. M. Kacmarek
The Relationship Between Gas Delivery Patterns and the Lower Inflection Point of the Pressure-Volume Curve During Partial Liquid Ventilation*
Chest, January 1, 2000; 117(1): 191 - 198.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1999 American Thoracic Society