help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by ARENS, R.
Right arrow Articles by GRUNSTEIN, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by ARENS, R.
Right arrow Articles by GRUNSTEIN, M. M.

Am. J. Respir. Crit. Care Med., Volume 158, Number 5, November 1998, 1403-1409

Altered Lung Mechanics after Double-Lung Transplantation

RAANAN ARENS, JOSEPH M. MCDONOUGH, HUAQING ZHAO, NANCY P. BLUMENTHAL, ROBERT M. KOTLOFF, and MICHAEL M. GRUNSTEIN

Divisions of Pulmonary Medicine, Biostatistics and Epidemiology, Children's Hospital of Philadelphia, Department of Pediatrics; and Divisions of Pulmonary and Critical Care, University of Pennsylvania Medical Center, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania

We studied lung mechanics and small airways function in 15 patients after double-lung (DL) transplantation. Patients were classified as stable (DL-S, n = 11), or having obliterative bronchiolitis syndrome (DL-OBS, n = 4). We performed pulmonary function tests (PFT), measured slope of phase 3 of the single-breath nitrogen test (N2SP3), and obtained pressure-volume curves and values: chord compliance (Cst,L), specific chord compliance (SCst,L), and elastic recoil pressure at 90% TLC. PFT showed mild restrictive pattern in DL-S and severe obstructive lung disease in DL-OBS. The N2SP3 measurement indicated small airways dysfunction in 82% of DL-S and in all DL-OBS patients. The Cst,L was 0.24 ± 0.08 L/cm H2O in DL-S and 0.16 ± 0.05 L/cm H2O in DL-OBS, both lower than control subjects 0.34 ± 0.09 L/cm H2O (p < 0.01; p < 0.001). Moreover, SCst,L was 0.09 ± 0.03 cm H2O-1 in DL-S, and 0.05 ± 0.02 cm H2O-1 in DL-OBS, significantly lower than control subjects 0.12 ± 0.02 cm H2O-1 (p < 0.05; p < 0.001). Elastic recoil at 90% TLC was normal in 14 of 15 patients. We found a linear correlation between N2SP3 and FEV1, and between FEV1 and Cst,L and SCst,L for combined DL-S and DL-OBS. Reduced compliance near FRC with normal elastic recoil at high lung volumes does not suggest changes in lung parenchyma. We speculate that structural or functional alterations in small airways may have contributed to low compliance measurements. Of special concern are our findings that DL-S had significant small airways dysfunction and reduced compliance in a pattern similar to the DL-OBS, only smaller in magnitude.




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
A. Van Muylem, C. Knoop, and M. Estenne
Early Detection of Chronic Pulmonary Allograft Dysfunction by Exhaled Biomarkers
Am. J. Respir. Crit. Care Med., April 1, 2007; 175(7): 731 - 736.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. ESTENNE, A. VAN MUYLEM, C. KNOOP, M. ANTOINE, and the Brussels Lung Transplant Group
Detection of Obliterative Bronchiolitis after Lung Transplantation by Indexes of Ventilation Distribution
Am. J. Respir. Crit. Care Med., September 1, 2000; 162(3): 1047 - 1051.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
SMALL AIRWAY DYSFUNCTION AFTER LUNG TRANSPLANTATION
Am. J. Respir. Crit. Care Med., May 1, 1999; 159(5): 1683 - 1683.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1998 American Thoracic Society