help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by VALTIER, B.
Right arrow Articles by PAYEN, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by VALTIER, B.
Right arrow Articles by PAYEN, D. M.

Am. J. Respir. Crit. Care Med., Volume 158, Number 1, July 1998, 77-83

Noninvasive Monitoring of Cardiac Output in Critically Ill Patients Using Transesophageal Doppler

BRUNO VALTIER, BERNARD P. CHOLLEY, JEAN-PIERRE BELOT, JEAN-EMMANUEL de la COUSSAYE, JOAQUIM MATEO, and DIDIER M. PAYEN

Department of Anesthesiology, Lariboisière Hospital, Paris; Medical Intensive Care, Louis Mourier Hospital, Colombes; and Department of Anesthesiology, Nîmes, France

Measurement of cardiac output using thermodilution technique in mechanically ventilated patients is associated with significant morbidity. The goal of the present study was to assess the validity of cardiac output measurement using transesophageal Doppler in critically ill patients. Forty-six patients from three different intensive care units underwent 136 paired cardiac output measurements using thermodilution (COTH) and transesophageal Doppler (COTED). In addition, simultaneous suprasternal Doppler and indirect calorimetry (Fick principle) were used to measure cardiac output in 26 patients from one center. A good correlation was found between COTH and COTED (r = 0.95), with a small systematic underestimation (bias = 0.24 L/min) using transesophageal Doppler. The limits of agreement between COTH and COTED were +2 L/min and -1.5 L/min. Variations in cardiac output between two consecutive measures using either transesophageal Doppler or thermodilution techniques were similar in direction and magnitude (bias = 0 L/min; limits of agreement = ±1.7 L/min). Suprasternal Doppler and indirect calorimetry yielded similar correlations and agreements in the subset of patients in whom they were used. These results confirm that transesophageal Doppler can provide a noninvasive, clinically useful estimate of cardiac output and detect hemodynamic changes in mechanically ventilated, critically ill patients.




This article has been cited by other articles:


Home page
ChestHome page
M. R. Pinsky
Hemodynamic Evaluation and Monitoring in the ICU
Chest, December 1, 2007; 132(6): 2020 - 2029.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
J-H. Lee, J-T. Kim, S. Z. Yoon, Y-J. Lim, Y. Jeon, J-H. Bahk, and C. S. Kim
Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
Br. J. Anaesth., September 1, 2007; 99(3): 343 - 348.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. Monsel, A. Salvat-Toussaint, P. Durand, V. Haas, C. Baujard, P. Rouleau, S. El Aouadi, D. Benhamou, and K. Asehnoune
The Transesophageal Doppler and Hemodynamic Effects of Epidural Anesthesia in Infants Anesthetized with Sevoflurane and Sufentanil
Anesth. Analg., July 1, 2007; 105(1): 46 - 50.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
W. Isakow and D. P. Schuster
Extravascular lung water measurements and hemodynamic monitoring in the critically ill: bedside alternatives to the pulmonary artery catheter
Am J Physiol Lung Cell Mol Physiol, December 1, 2006; 291(6): L1118 - L1131.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
O. Raux, A. Rochette, E. Morau, C. Dadure, C. Vergnes, and X. Capdevila
The Effects of Spread of Block and Adrenaline on Cardiac Output After Epidural Anesthesia in Young Children: A Randomized, Double-Blind, Prospective Study
Anesth. Analg., April 1, 2004; 98(4): 948 - 955.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. Larousse, K. Asehnoune, B. Dartayet, P. Albaladejo, A.-M. Dubousset, F. Gauthier, and D. Benhamou
The Hemodynamic Effects of Pediatric Caudal Anesthesia Assessed by Esophageal Doppler
Anesth. Analg., May 1, 2002; 94(5): 1165 - 1168.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
K. B. Laupland and C. J. Bands
Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a review: [Revue de l'utilite du Doppler oesophagien comme moniteur hemodynamique a effraction minimale]
Can J Anesth, April 1, 2002; 49(4): 393 - 401.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
H. A. Leather and P. F. Wouters
Oesophageal Doppler monitoring overestimates cardiac output during lumbar epidural anaesthesia
Br. J. Anaesth., June 1, 2001; 86(6): 794 - 797.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
P. G. Duane and G. L. Colice
Impact of Noninvasive Studies to Distinguish Volume Overload From ARDS in Acutely Ill Patients With Pulmonary Edema : Analysis of the Medical Literature From 1966 to 1998
Chest, December 1, 2000; 118(6): 1709 - 1717.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
P. E. Marik
Pulmonary Artery Catheterization and Esophageal Doppler Monitoring in the ICU
Chest, October 1, 1999; 116(4): 1085 - 1091.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1998 American Thoracic Society