help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by DAVIS, S.
Right arrow Articles by TEPPER, R. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by DAVIS, S.
Right arrow Articles by TEPPER, R. S.

Am. J. Respir. Crit. Care Med., Volume 158, Number 1, July 1998, 148-152

Effect of Continuous Positive Airway Pressure on Forced Expiratory Flows in Infants with Tracheomalacia

STEPHANIE DAVIS, MARCUS JONES, JEFF KISLING, CONNIE ANGELICCHIO, and ROBERT S. TEPPER

Department of Pediatrics, Indiana University Medical Center, James Whitcomb Riley Hospital for Children, Indianapolis, Indiana

Continuous positive airway pressure (CPAP) is used to minimize airway collapse in infants with tracheomalacia. Forced expiratory flows (FEFs) at functional residual capacity (FRC) increase with increasing CPAP in infants with tracheomalacia, and it has been suggested that CPAP prevents airway collapse by "stenting" the airway open. Since FEF is greater at higher than at lower lung volumes, we evaluated whether the increase in flow measured at FRC (V FRC) with CPAP could be explained by the increase in FRC with CPAP. We measured full FEF-volume curves at CPAP levels of 0, 4, and 8 cm H2O in six infants with tracheomalacia and five healthy control infants. In both groups of infants, FVC did not change with CPAP; however, inspiratory capacity (IC) decreased and thus FRC increased with increasing CPAP. FEFs at FRC increased with increasing levels of CPAP; however, the FEFs at 50% and 75% of expired volume were not different for the three levels of CPAP for both groups of infants. Our finding that FEFs measured at the same lung volumes did not differ for the different levels of CPAP indicates that CPAP affects forced flows primarily by increasing lung volume.




This article has been cited by other articles:


Home page
RadiologyHome page
E. Y. Lee and P. M. Boiselle
Tracheobronchomalacia in Infants and Children: Multidetector CT Evaluation
Radiology, July 1, 2009; 252(1): 7 - 22.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement: Raised Volume Forced Expirations in Infants: Guidelines for Current Practice
Am. J. Respir. Crit. Care Med., December 1, 2005; 172(11): 1463 - 1471.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. K. Lambert, R. G. Castile, and R. S. Tepper
Model of forced expiratory flows and airway geometry in infants
J Appl Physiol, February 1, 2004; 96(2): 688 - 692.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
C. Morley
Continuous distending pressure
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 1999; 81(2): 152F - 156.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1998 American Thoracic Society
  ATS Par News