help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by FARRÉ, R.
Right arrow Articles by NAVAJAS, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by FARRÉ, R.
Right arrow Articles by NAVAJAS, D.

Am. J. Respir. Crit. Care Med., Volume 157, Number 6, June 1998, 1855-1863

Flow-dependent Positive Airway Pressure to Maintain Airway Patency in Sleep Apnea-Hypopnea Syndrome

RAMON FARRÉ, RENÉ PESLIN, JOSEP M. MONTSERRAT, MAR ROTGER, and DANIEL NAVAJAS

Lab. Biofísica i Bioenginyeria, Facultat de Medicina, Institute d'Investigacions Biomèdiques Agusti Pi i Sunyer, Universitat de Barcelona, Spain; Unité 14 de Physiopathologie Respiratoire INSERM, Nancy, France; and Servei de Pneumologia, Hospital Clinic Provincial, Institute d'Investigacions Biomèdiques Agusti Pi i Sunyer, Barcelona, Spain

Airway obstruction in patients with sleep apnea-hypopnea syndrome (SAHS) is due to increased critical pressure (Pcrit) of the upper airway. The ideal nasal pressure (Pn) to maintain airway patency should consist of the constant term to account for Pcrit and a term (Rn · V) proportional to flow (V) to account for the dynamic pressure drop through nasal resistance (R n). Continuous positive airway pressure (CPAP) applied to avoid flow limitation results in a Pn greater than required over most of the breathing cycle. The aim was to assess a flow-dependent positive airway pressure (FDPAP) based on adapting Pn to the instantaneous flow: Pn = P0 + k · V. FDPAP was tested on collapsible airway models and its applicability was assessed in nine patients with SAHS during sleep. In models, FDPAP prevented flow limitation with lower mean P n and work of breathing than CPAP. In patients FDPAP allowed the patients to breathe normally with a mean Pn (6.6 ± 1.2 cm H2O) systematically and significantly (p < 0.05, paired t test) lower than when applying CPAP (9.1 ± 1.2 cm H2O). The results found in models and in patients suggest that adapting the applied nasal pressure to the instantaneous breathing flow may be of potential practical interest in SAHS.




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
R. Farre, J. M. Montserrat, J. Rigau, X. Trepat, P. Pinto, and D. Navajas
Response of Automatic Continuous Positive Airway Pressure Devices to Different Sleep Breathing Patterns: A Bench Study
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 469 - 473.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. FARRE, M. MANCINI, M. ROTGER, M. FERRER, J. ROCA, and D. NAVAJAS
Oscillatory Resistance Measured during Noninvasive Proportional Assist Ventilation
Am. J. Respir. Crit. Care Med., September 1, 2001; 164(5): 790 - 794.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
P. Lévy and J.-L. Pépin
Autoadjusting Continuous Positive Airway Pressure . What Can We Expect?
Am. J. Respir. Crit. Care Med., May 1, 2001; 163(6): 1295 - 1296.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1998 American Thoracic Society