help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by STEPHAN, F.
Right arrow Articles by FAGON, J.-Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by STEPHAN, F.
Right arrow Articles by FAGON, J.-Y.

Am. J. Respir. Crit. Care Med., Vol 157, No. 1, Jan 1998, 50-56.

Determination of total effective vascular compliance in patients with sepsis syndrome [In Process Citation]

F Stephan, A Novara, B Tournier, JM Maillet, GM London, ME Safar and JY Fagon
Department of Internal Medicine, INSERM U 337, Broussais Hospital, Paris, France.

Changes in capacitance vessels have important consequences on cardiac filling pressure and fluid volume distribution in patients with sepsis syndrome. Vascular compliance may be evaluated from the slope of the relationship between changes in total blood volume (deltaTBV) and changes in central venous pressure (deltaCVP) during acute volume expansion (450 ml of gelatin fluid over 6 min), i.e., from the deltaTBV/deltaCVP ratio. The mean ratio (ml x mm Hg-1 x kg-1) was 2.03 +/- 0.21 in control subjects, 1.43 +/- 0.25 in mechanically ventilated patients without sepsis syndrome, and 0.94 +/- 0.24 in mechanically ventilated patients with sepsis syndrome (p < 0.0001 versus the other two groups). Based on echocardiographic determinations, cardiac performance was constantly found within the normal range (cardiac output ranged from 5.6 +/- 1.2 to 6.7 +/- 2.0 L/min in nonseptic patients from 6.8 +/- 1.9 to 7.8 +/- 2.2 in septic patients). Effective compliance of the total vascular bed is therefore reduced in patients with sepsis syndrome, independently of the hemodynamic modifications due to mechanical ventilation.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
F. Stephan, A. Flahault, N. Dieudonne, J. Hollande, F. Paillard, and F. Bonnet
Clinical evaluation of circulating blood volume in critically ill patients--contribution of a clinical scoring system{{dagger}}
Br. J. Anaesth., June 1, 2001; 86(6): 754 - 762.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.