help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lloberes, P.
Right arrow Articles by Rodriguez-Roisin, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lloberes, P.
Right arrow Articles by Rodriguez-Roisin, R.

Am. J. Respir. Crit. Care Med., Vol 154, No. 6, Dec 1996, 1755-1758.

Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome

P Lloberes, E Ballester, JM Montserrat, E Botifoll, A Ramirez, A Reolid, C Gistau and R Rodriguez-Roisin
Department of Medicine, University of Barcelona, Spain.

Automatic CPAP (auto-CPAP) is engineered to automatically provide a positive pressure to the upper airway in response to apnea, hypopnea, airflow limitation, or snoring in patients with the sleep apnea/ hypopnea syndrome (SAHS). Self-adjusted CPAP has theoretical advantages over traditional fixed CPAP. We investigated the value of auto-CPAP regulation in 20 patients with SAHS in order to predict future fixed- level CPAP needs, as an alternative method to conventional polysomnographically (PSG)-controlled CPAP titration. This was accomplished through comparison of the optimal CPAP level obtained with PSG with that obtained with auto-CPAP. There were no significant differences between the optimal CPAP level achieved with full PSG or with auto-CPAP. As a secondary analysis, we analyzed auto-CPAP performance with regard to sleep-stage distribution and arousals in a group of nine male patients, and compared it with the previous group of 20 patients in which manually CPAP titration was guided by PSG. After adequate CPAP was reached, upward and downward fluctuations in the CPAP level had no significant effect on sleep architecture or fragmentation. We conclude that auto-CPAP permits the prediction of future fixed-level CPAP needs, and does so without sleep disruption.


This article has been cited by other articles:


Home page
ACCP Sleep Med Brd RevHome page
N. S. Freedman
Positive Airway Pressure Therapy for Obstructive Sleep Apnea Syndrome: The Boards and Beyond
ACCP Sleep Med Brd Rev, January 1, 2009; 4(0): 293 - 312.
[Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
M. H. Sanders, J. M. Montserrat, R. Farre, and R. J. Givelber
Positive Pressure Therapy: A Perspective on Evidence-based Outcomes and Methods of Application
Proceedings of the ATS, February 15, 2008; 5(2): 161 - 172.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
V. Patruno, S. Aiolfi, G. Costantino, R. Murgia, C. Selmi, A. Malliani, and N. Montano
Fixed and Autoadjusting Continuous Positive Airway Pressure Treatments Are Not Similar in Reducing Cardiovascular Risk Factors in Patients With Obstructive Sleep Apnea
Chest, May 1, 2007; 131(5): 1393 - 1399.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. Rigau, J. M. Montserrat, H. Wohrle, D. Plattner, M. Schwaibold, D. Navajas, and R. Farre
Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
Chest, August 1, 2006; 130(2): 350 - 361.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
Y. Nussbaumer, K. E. Bloch, T. Genser, and R. Thurnheer
Equivalence of Autoadjusted and Constant Continuous Positive Airway Pressure in Home Treatment of Sleep Apnea
Chest, March 1, 2006; 129(3): 638 - 643.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. F. Masa, A. Jimenez, J. Duran, F. Capote, C. Monasterio, M. Mayos, J. Teran, L. Hernandez, F. Barbe, A. Maimo, et al.
Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Am. J. Respir. Crit. Care Med., December 1, 2004; 170(11): 1218 - 1224.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
F. Abdenbi, B. Chambille, and P. Escourrou
Bench testing of auto-adjusting positive airway pressure devices
Eur. Respir. J., October 1, 2004; 24(4): 649 - 658.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
A. Stammnitz, A. Jerrentrup, T. Penzel, J.H. Peter, C. Vogelmeier, and H.F. Becker
Automatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea
Eur. Respir. J., August 1, 2004; 24(2): 273 - 278.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. A. Pevernagie, P. M. Proot, K. B. Hertegonne, M. C. Neyens, K. P. Hoornaert, and R. A. Pauwels
Efficacy of Flow- vs Impedance-Guided Autoadjustable Continuous Positive Airway Pressure: A Randomized Cross-over Trial
Chest, July 1, 2004; 126(1): 25 - 30.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
O. Senn, T. Brack, F. Matthews, E. W. Russi, and K. E. Bloch
Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep Apnea
Am. J. Respir. Crit. Care Med., December 15, 2003; 168(12): 1506 - 1511.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
P. L. Smith, C. P. O'Donnell, L. Allan, and A. R. Schwartz
A Physiologic Comparison of Nasal and Oral Positive Airway Pressure
Chest, March 1, 2003; 123(3): 689 - 694.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. Kessler, E. Weitzenblum, A. Chaouat, C. Iamandi, and T. Alliotte
Evaluation of Unattended Automated Titration To Determine Therapeutic Continuous Positive Airway Pressure in Patients With Obstructive Sleep Apnea
Chest, March 1, 2003; 123(3): 704 - 710.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. Farre, J. M. Montserrat, J. Rigau, X. Trepat, P. Pinto, and D. Navajas
Response of Automatic Continuous Positive Airway Pressure Devices to Different Sleep Breathing Patterns: A Bench Study
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 469 - 473.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
O. Marrone, G. Insalaco, M. R. Bonsignore, S. Romano, A. Salvaggio, and G. Bonsignore
Sleep Structure Correlates of Continuous Positive Airway Pressure Variations During Application of an Autotitrating Continuous Positive Airway Pressure Machine in Patients With Obstructive Sleep Apnea Syndrome
Chest, March 1, 2002; 121(3): 759 - 767.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J.C. Rudkowski, P. Verschelden, and R.J. Kimoff
Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea
Eur. Respir. J., September 1, 2001; 18(3): 535 - 541.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. S. C Hui, D. K. L. Choy, T. S. T. Li, F. W. S. Ko, K. K. Wong, J. K. W. Chan, and C. K. W. Lai
Determinants of Continuous Positive Airway Pressure Compliance in a Group of Chinese Patients With Obstructive Sleep Apnea
Chest, July 1, 2001; 120(1): 170 - 176.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
M P Bureau and F Sériès
Comparison of two in-laboratory titration methods to determine effective pressure levels in patients with obstructive sleep apnoea
Thorax, September 1, 2000; 55(9): 741 - 745.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
F. SÉRIÈS
Accuracy of an Unattended Home CPAP Titration in the Treatment of Obstructive Sleep Apnea
Am. J. Respir. Crit. Care Med., July 1, 2000; 162(1): 94 - 97.
[Abstract] [Full Text]


Home page
ChestHome page
D. S. C. Hui, J. K. W. Chan, D. K. L. Choy, F. W. S. Ko, T. S. T. Li, R. C. C. Leung, and C. K. W. Lai
Effects of Augmented Continuous Positive Airway Pressure Education and Support on Compliance and Outcome in a Chinese Population
Chest, May 1, 2000; 117(5): 1410 - 1416.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. I. Loube
Technologic Advances in the Treatment of Obstructive Sleep Apnea Syndrome
Chest, November 1, 1999; 116(5): 1426 - 1433.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. I. Loube, P. C. Gay, K. P. Strohl, A. I. Pack, D. P. White, and N. A. Collop
Indications for Positive Airway Pressure Treatment of Adult Obstructive Sleep Apnea Patients: A Consensus Statement
Chest, March 1, 1999; 115(3): 863 - 866.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
E. BALLESTER, J. R. BADIA, L. HERNÁNDEZ, E. CARRASCO, J. de PABLO, C. FORNAS, R. RODRIGUEZ-ROISIN, and J. M. MONTSERRAT
Evidence of the Effectiveness of Continuous Positive Airway Pressure in the Treatment of Sleep Apnea/Hypopnea Syndrome
Am. J. Respir. Crit. Care Med., February 1, 1999; 159(2): 495 - 501.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 1996 American Thoracic Society
  Tobacco