Am. J. Respir. Crit. Care Med., Vol 154, No. 6, Dec 1996, 1755-1758.
Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome
P Lloberes, E Ballester, JM Montserrat, E Botifoll, A Ramirez, A Reolid, C Gistau and R Rodriguez-Roisin
Department of Medicine, University of Barcelona, Spain.
Automatic CPAP (auto-CPAP) is engineered to automatically provide a
positive pressure to the upper airway in response to apnea, hypopnea,
airflow limitation, or snoring in patients with the sleep apnea/ hypopnea
syndrome (SAHS). Self-adjusted CPAP has theoretical advantages over
traditional fixed CPAP. We investigated the value of auto-CPAP regulation
in 20 patients with SAHS in order to predict future fixed- level CPAP
needs, as an alternative method to conventional polysomnographically
(PSG)-controlled CPAP titration. This was accomplished through comparison
of the optimal CPAP level obtained with PSG with that obtained with
auto-CPAP. There were no significant differences between the optimal CPAP
level achieved with full PSG or with auto-CPAP. As a secondary analysis, we
analyzed auto-CPAP performance with regard to sleep-stage distribution and
arousals in a group of nine male patients, and compared it with the
previous group of 20 patients in which manually CPAP titration was guided
by PSG. After adequate CPAP was reached, upward and downward fluctuations
in the CPAP level had no significant effect on sleep architecture or
fragmentation. We conclude that auto-CPAP permits the prediction of future
fixed-level CPAP needs, and does so without sleep disruption.
This article has been cited by other articles:

|
 |

|
 |
 
M. H. Sanders, J. M. Montserrat, R. Farre, and R. J. Givelber
Positive Pressure Therapy: A Perspective on Evidence-based Outcomes and Methods of Application
Proceedings of the ATS,
February 15, 2008;
5(2):
161 - 172.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
V. Patruno, S. Aiolfi, G. Costantino, R. Murgia, C. Selmi, A. Malliani, and N. Montano
Fixed and Autoadjusting Continuous Positive Airway Pressure Treatments Are Not Similar in Reducing Cardiovascular Risk Factors in Patients With Obstructive Sleep Apnea
Chest,
May 1, 2007;
131(5):
1393 - 1399.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Rigau, J. M. Montserrat, H. Wohrle, D. Plattner, M. Schwaibold, D. Navajas, and R. Farre
Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
Chest,
August 1, 2006;
130(2):
350 - 361.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. Nussbaumer, K. E. Bloch, T. Genser, and R. Thurnheer
Equivalence of Autoadjusted and Constant Continuous Positive Airway Pressure in Home Treatment of Sleep Apnea
Chest,
March 1, 2006;
129(3):
638 - 643.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. F. Masa, A. Jimenez, J. Duran, F. Capote, C. Monasterio, M. Mayos, J. Teran, L. Hernandez, F. Barbe, A. Maimo, et al.
Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Am. J. Respir. Crit. Care Med.,
December 1, 2004;
170(11):
1218 - 1224.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Abdenbi, B. Chambille, and P. Escourrou
Bench testing of auto-adjusting positive airway pressure devices
Eur. Respir. J.,
October 1, 2004;
24(4):
649 - 658.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Stammnitz, A. Jerrentrup, T. Penzel, J.H. Peter, C. Vogelmeier, and H.F. Becker
Automatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea
Eur. Respir. J.,
August 1, 2004;
24(2):
273 - 278.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. A. Pevernagie, P. M. Proot, K. B. Hertegonne, M. C. Neyens, K. P. Hoornaert, and R. A. Pauwels
Efficacy of Flow- vs Impedance-Guided Autoadjustable Continuous Positive Airway Pressure: A Randomized Cross-over Trial
Chest,
July 1, 2004;
126(1):
25 - 30.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
O. Senn, T. Brack, F. Matthews, E. W. Russi, and K. E. Bloch
Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep Apnea
Am. J. Respir. Crit. Care Med.,
December 15, 2003;
168(12):
1506 - 1511.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. L. Smith, C. P. O'Donnell, L. Allan, and A. R. Schwartz
A Physiologic Comparison of Nasal and Oral Positive Airway Pressure
Chest,
March 1, 2003;
123(3):
689 - 694.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Kessler, E. Weitzenblum, A. Chaouat, C. Iamandi, and T. Alliotte
Evaluation of Unattended Automated Titration To Determine Therapeutic Continuous Positive Airway Pressure in Patients With Obstructive Sleep Apnea
Chest,
March 1, 2003;
123(3):
704 - 710.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Farre, J. M. Montserrat, J. Rigau, X. Trepat, P. Pinto, and D. Navajas
Response of Automatic Continuous Positive Airway Pressure Devices to Different Sleep Breathing Patterns: A Bench Study
Am. J. Respir. Crit. Care Med.,
August 15, 2002;
166(4):
469 - 473.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
O. Marrone, G. Insalaco, M. R. Bonsignore, S. Romano, A. Salvaggio, and G. Bonsignore
Sleep Structure Correlates of Continuous Positive Airway Pressure Variations During Application of an Autotitrating Continuous Positive Airway Pressure Machine in Patients With Obstructive Sleep Apnea Syndrome
Chest,
March 1, 2002;
121(3):
759 - 767.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J.C. Rudkowski, P. Verschelden, and R.J. Kimoff
Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea
Eur. Respir. J.,
September 1, 2001;
18(3):
535 - 541.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. S. C Hui, D. K. L. Choy, T. S. T. Li, F. W. S. Ko, K. K. Wong, J. K. W. Chan, and C. K. W. Lai
Determinants of Continuous Positive Airway Pressure Compliance in a Group of Chinese Patients With Obstructive Sleep Apnea
Chest,
July 1, 2001;
120(1):
170 - 176.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M P Bureau and F Sériès
Comparison of two in-laboratory titration methods to determine effective pressure levels in patients with obstructive sleep apnoea
Thorax,
September 1, 2000;
55(9):
741 - 745.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
F. SÉRIÈS
Accuracy of an Unattended Home CPAP Titration in the Treatment of Obstructive Sleep Apnea
Am. J. Respir. Crit. Care Med.,
July 1, 2000;
162(1):
94 - 97.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
D. S. C. Hui, J. K. W. Chan, D. K. L. Choy, F. W. S. Ko, T. S. T. Li, R. C. C. Leung, and C. K. W. Lai
Effects of Augmented Continuous Positive Airway Pressure Education and Support on Compliance and Outcome in a Chinese Population
Chest,
May 1, 2000;
117(5):
1410 - 1416.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. I. Loube
Technologic Advances in the Treatment of Obstructive Sleep Apnea Syndrome
Chest,
November 1, 1999;
116(5):
1426 - 1433.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. I. Loube, P. C. Gay, K. P. Strohl, A. I. Pack, D. P. White, and N. A. Collop
Indications for Positive Airway Pressure Treatment of Adult Obstructive Sleep Apnea Patients: A Consensus Statement
Chest,
March 1, 1999;
115(3):
863 - 866.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. BALLESTER, J. R. BADIA, L. HERNÁNDEZ, E. CARRASCO, J. de PABLO, C. FORNAS, R. RODRIGUEZ-ROISIN, and J. M. MONTSERRAT
Evidence of the Effectiveness of Continuous Positive Airway Pressure in the Treatment of Sleep Apnea/Hypopnea Syndrome
Am. J. Respir. Crit. Care Med.,
February 1, 1999;
159(2):
495 - 501.
[Abstract]
[Full Text]
|
 |
|
Copyright © 1996 American Thoracic Society
|
|
|